Glucose Monitoring After Fruit Peeling: Pseudohyperglycemia When Neglecting Hand Washing Before Fingertip Blood Sampling
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To examine whether hand contamination with fruit results in a false blood glucose (BG) reading using capillary fingertip blood sample. RESEARCH DESIGN AND METHODS: The study subjects were healthy volunteers with normal glucose tolerance test. Capillary BG samples were collected from the fingertip after peeling orange, grape, or kiwi fruit, followed by no action, washing hands with tap water, or rubbing the fingertip with an alcohol swab, then analyzed with glucose monitors. RESULTS: The BG levels measured after peeling any of the fruits, followed by washing hands, were similar to the control subjects (no fruit handling), but the levels after fruit peeling, followed by no washing, were abnormally and significantly high, even when the fingertip was cleaned once or five times with an alcohol swab before blood sampling. CONCLUSIONS: To avoid overestimation of blood glucose using portable monitors, the hands should be washed before monitoring capillary BG, especially after fruit has been handled.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O’Kane, M. J., Bunting, B., Copeland, M., & Coates, V. E. (2008) · BMJ · doi:10.1136/bmj.39534.571644.be · Cited by 326
Faas, A., Schellevis, F. G., & Eijk, J. T. M. V. (1997) · Diabetes Care · doi:10.2337/diacare.20.9.1482 · Cited by 139
Research works printed but not linked: 4
- Coster, 2000, Self-monitoring in type 2 diabetes mellitus: a meta-analysis, Diabet Med, 17, 755, 10.1046/j.1464-5491.2000.00390.x · DOI · Paper page
- Kennedy, 2001, Self-monitoring of blood glucose in type 2 diabetes: time for evidence of efficacy, Diabetes Care, 24, 977, 10.2337/diacare.24.6.977 · DOI
- Haupt, 2005, The effects of skin temperature and testing site on blood glucose measurements taken by a modern blood glucose monitoring device, Diabetes Technol Ther, 7, 602, 10.1089/dia.2005.7.597 · DOI
- El Khoury, 2008, Pseudohypoglycemia: a cause for unreliable finger-stick glucose measurements, Endocr Pract, 14, 337, 10.4158/EP.ep.14.3.337 · doi:10.4158/ep.ep.14.3.337
Cited by
Interferences and Limitations in Blood Glucose Self-Testing: An Overview of the Current Knowledge
Erbach, M., Freckmann, G., Hinzmann, R., Kulzer, B., Ziegler, R., Heinemann, L., & Schnell, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816641433 · Cited by 115
Pleus, S., Baumstark, A., Jendrike, N., Mende, J., Link, M., Zschornack, E., Haug, C., & Freckmann, G. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001067 · Cited by 63
Baumstark, A., Jendrike, N., Pleus, S., Haug, C., & Freckmann, G. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0408 · Cited by 22
Glucose meters—fit for clinical purpose
Tirimacco, R., Koumantakis, G., Erasmus, R., Mosca, A., Sandberg, S., Watson, I. D., Goldsmith, B., & Gillery, P. (2013) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm-2013-0011 · Cited by 20
Metadata
- Authors
- Hirose, T., Mita, T., Fujitani, Y., Kawamori, R., & Watada, H.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2011-02-17
- Volume
- 34
- Issue
- 3
- Pages
- 596-597
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1986883676
- Cited by
- 50
- References
- 2
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.