Abstract
OBJECTIVE: To compare the pharmacokinetics, pharmacodynamics, and safety of insulin lispro or regular human insulin (RHI) with or without recombinant human hyaluronidase (rHuPH20) administered before a standardized meal. RESEARCH DESIGN AND METHODS: In this four-way, crossover study, 22 patients with type 1 diabetes received injections of individually optimized doses of lispro or RHI with and without rHuPH20 before a liquid meal. RESULTS: With rHuPH20 coadministration, early insulin exposure (0–60 min) increased by 54% (P = 0.0011) for lispro and 206% (P < 0.0001) for RHI compared with the respective insulin alone. Peak blood glucose decreased 26 mg/dL for lispro (P = 0.002) and 24 mg/dL for RHI (P = 0.017), reducing hyperglycemic excursions (area under the curve for blood glucose >140 mg/dL) by 79% (P = 0.09) and 85% (P = 0.049), respectively. Rates of hypoglycemia were comparable for lispro with or without rHuPH20, whereas coadministration of RHI and rHuPH20 reduced hypoglycemia. CONCLUSIONS: Lispro or RHI with rHuPH20 produced earlier and greater peak insulin concentrations and improved postprandial glycemic control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of Medical Care in Diabetes—2009
American Diabetes Association (2009) · Diabetes Care · doi:10.2337/dc09-s013 · Cited by 2,167
Cited by
Russell-Jones, D., Bode, B. W., De Block, C., Franek, E., Heller, S. R., Mathieu, C., Philis-Tsimikas, A., Rose, L., Woo, V. C., Østerskov, A. B., et al. (2017) · Diabetes Care · doi:10.2337/dc16-1771 · Cited by 177
Mathieu, C., Bode, B. W., Franek, E., Philis‐Tsimikas, A., Rose, L., Graungaard, T., Birk Østerskov, A., & Russell‐Jones, D. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13205 · Cited by 95
Moving toward the ideal insulin for insulin pumps
Cengiz, E., Bode, B., Van Name, M., & Tamborlane, W. V. (2016) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1109442 · Cited by 38
Hompesch, M., Muchmore, D. B., Morrow, L., Ludington, E., & Vaughn, D. E. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0117 · Cited by 25
Self-citation
Metadata
- Authors
- Hompesch, M., Muchmore, D. B., Morrow, L., & Vaughn, D. E.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2011-02-17
- Volume
- 34
- Issue
- 3
- Pages
- 666-668
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2111777136
- Cited by
- 58
- References
- 1
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerated Insulin Pharmacokinetics and Improved Postprandial Glycemic Control in Patients With Type 1 Diabetes After Coadministration of Prandial Insulins With Hyaluronidase. https://app.cochat.ai/papers/10.2337/dc10-1892
- The paper
- Hompesch, M., Muchmore, D. B., Morrow, L., & Vaughn, D. E. (2011). Accelerated Insulin Pharmacokinetics and Improved Postprandial Glycemic Control in Patients With Type 1 Diabetes After Coadministration of Prandial Insulins With Hyaluronidase. Diabetes Care. https://doi.org/10.2337/dc10-1892
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.