CoChat

Assessment of Patient-Led or Physician-Driven Continuous Glucose Monitoring in Patients With Poorly Controlled Type 1 Diabetes Using Basal-Bolus Insulin Regimens

Open access
Riveline, Jean-Pierre, Schaepelynck, Pauline, Chaillous, Lucy, Renard, Eric, Sola-Gazagnes, Agnès, Penfornis, Alfred, Tubiana-Rufi, Nadia, Sulmont, Véronique, Catargi, Bogdan, Lukas, Céline, Radermecker, Régis P., Thivolet, Charles, Moreau, François, Benhamou, Pierre-Yves, Guerci, Bruno, Leguerrier, Anne-Marie, Millot, Luc, Sachon, Claude, Charpentier, Guillaume, Hanaire, Hélène, for the EVADIAC Sensor Study Group · 2012 · Diabetes Care
Cited by 94

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The benefits of real-time continuous glucose monitoring (CGM) have been demonstrated in patients with type 1 diabetes. Our aim was to compare the effect of two modes of use of CGM, patient led or physician driven, for 1 year in subjects with poorly controlled type 1 diabetes. RESEARCH DESIGN AND METHODS: Patients with type 1 diabetes aged 8–60 years with HbA1c ≥8% were randomly assigned to three groups (1:1:1). Outcomes for glucose control were assessed at 1 year for two modes of CGM (group 1: patient led; group 2: physician driven) versus conventional self-monitoring of blood glucose (group 3: control). RESULTS: A total of 257 subjects with type 1 diabetes underwent screening. Of these, 197 were randomized, with 178 patients completing the study (age: 36 ± 14 years; HbA1c: 8.9 ± 0.9%). HbA1c improved similarly in both CGM groups and was reduced compared with the control group (group 1 vs. group 3: −0.52%, P = 0.0006; group 2 vs. group 3: −0.47%, P = 0.0008; groups 1 + 2 vs. group 3: −0.50%, P < 0.0001). The incidence of hypoglycemia was similar in the three groups. Patient SF-36 questionnaire physical health score improved in both experimental CGM groups (P = 0.004). Sensor consumption was 34% lower in group 2 than in group 1 (median [Q1–Q3] consumption: group 1: 3.42/month [2.20–3.91] vs. group 2: 2.25/month [1.27–2.99], P = 0.001). CONCLUSIONS: Both patient-led and physician-driven CGM provide similar long-term improvement in glucose control in patients with poorly controlled type 1 diabetes, but the physician-driven CGM mode used fewer sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc11-2021

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 94

Metadata

Authors
Riveline, J.-P., Schaepelynck, P., Chaillous, L., Renard, E., Sola-Gazagnes, A., Penfornis, A., Tubiana-Rufi, N., Sulmont, V., Catargi, B., Lukas, C., Radermecker, R. P., Thivolet, C., Moreau, F., Benhamou, P.-Y., Guerci, B., Leguerrier, A.-M., Millot, L., Sachon, C., Charpentier, G., Hanaire, H., & for the EVADIAC Sensor Study Group
Venue
Diabetes Care
Published
2012-04-11
Volume
35
Issue
5
Pages
965-971
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W1987616068
Cited by
94
References
4
FWCI
5.52
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.