CoChat

LOGIC-Insulin Algorithm–Guided Versus Nurse-Directed Blood Glucose Control During Critical Illness

Open access
Van Herpe, Tom, Mesotten, Dieter, Wouters, Pieter J., Herbots, Jeroen, Voets, Evy, Buyens, Jo, De Moor, Bart, Van den Berghe, Greet · 2013 · Diabetes Care
Cited by 95

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Tight blood glucose control (TGC) in critically ill patients is difficult and labor intensive, resulting in poor efficacy of glycemic control and increased hypoglycemia rate. The LOGIC-Insulin computerized algorithm has been developed to assist nurses in titrating insulin to maintain blood glucose levels at 80–110 mg/dL (normoglycemia) and to avoid severe hypoglycemia (<40 mg/dL). The objective was to validate clinically LOGIC-Insulin relative to TGC by experienced nurses. RESEARCH DESIGN AND METHODS: The investigator-initiated LOGIC-1 study was a prospective, parallel-group, randomized, controlled clinical trial in a single tertiary referral center. A heterogeneous mix of 300 critically ill patients were randomized, by concealed computer allocation, to either nurse-directed glycemic control (Nurse-C) or algorithm-guided glycemic control (LOGIC-C). Glycemic penalty index (GPI), a measure that penalizes both hypoglycemic and hyperglycemic deviations from normoglycemia, was the efficacy outcome measure, and incidence of severe hypoglycemia (<40 mg/dL) was the safety outcome measure. RESULTS: Baseline characteristics of 151 Nurse-C patients and 149 LOGIC-C patients and study times did not differ. The GPI decreased from 12.4 (interquartile range 8.2–18.5) in Nurse-C to 9.8 (6.0–14.5) in LOGIC-C (P < 0.0001). The proportion of study time in target range was 68.6 ± 16.7% for LOGIC-C patients versus 60.1 ± 18.8% for Nurse-C patients (P = 0.00016). The proportion of severe hypoglycemic events was decreased in the LOGIC-C group (Nurse-C 0.13%, LOGIC-C 0%; P = 0.015) but not when considered as a proportion of patients (Nurse-C 3.3%, LOGIC-C 0%; P = 0.060). Sampling interval was 2.2 ± 0.4 h in the LOGIC-C group versus 2.5 ± 0.5 h in the Nurse-C group (P < 0.0001). CONCLUSIONS: Compared with expert nurses, LOGIC-Insulin improved efficacy of TGC without increasing rate of hypoglycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc12-0584

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 95

Metadata

Authors
Van Herpe, T., Mesotten, D., Wouters, P. J., Herbots, J., Voets, E., Buyens, J., De Moor, B., & Van den Berghe, G.
Venue
Diabetes Care
Published
2013-01-17
Volume
36
Issue
2
Pages
188-194
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2107090345
Cited by
95
References
7
FWCI
6.21
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.