CoChat

Heart rate-corrected QT interval is an independent predictor of all-cause and cardiovascular mortality in individuals with type 2 diabetes: the diabetes heart study

Open access

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Heart rate–corrected QT (QTc) interval is associated with mortality in the general population, but this association is less clear in individuals with type 2 diabetes. We assessed the association of QTc interval with all-cause and cardiovascular disease (CVD) mortality in the Diabetes Heart Study. RESEARCH DESIGN AND METHODS: We studied 1,020 participants with type 2 diabetes (83% European Americans; 55% women; mean age 61.4 years) who were free of atrial fibrillation, major ventricular conduction defects, and antiarrhythmic therapy at baseline. QT duration was automatically calculated from a standard 12-lead electrocardiogram (ECG). Following American Heart Association/American College of Cardiology Foundation recommendations, a linear scale was used to correct the QT for heart rate. Using Cox regression, risk was estimated per 1-SD increase in QTc interval as well as prolonged QTc interval (>450 ms) vs. normal QTc interval for mortality. RESULTS: At baseline, the mean (SD) QTc duration was 414.9 ms (18.1), and 3.0% of participants had prolonged QTc. After a median follow-up time of 8.5 years (maximum follow-up time 13.9 years), 204 participants were deceased. In adjusted multivariate models, a 1-SD increase in QTc interval was associated with an 18% higher risk for all-cause mortality (hazard ratio 1.18 [95% CI 1.03–1.36]) and 29% increased risk for CVD mortality (1.29 [1.05–1.59]). Similar results were obtained when QTc interval was used as a categorical variable (prolonged vs. normal) (all-cause mortality 1.73 [0.95–3.15]; CVD mortality 2.86 [1.35–6.08]). CONCLUSIONS: Heart rate QTc interval is an independent predictor of all-cause and CVD mortality in this population with type 2 diabetes, suggesting that additional prognostic information may be available from this simple ECG measure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc13-1257

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Mortality risk associated with prolonged (>450 ms) vs. normal heart rate QTc interval: DHS.
Figure 1 Mortality risk associated with prolonged (>450 ms) vs. normal heart rate QTc interval: DHS.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Bazett, 1920, An analysis of the time-relations of electrocardiograms, Heart, 7, 353

Cited by

See all 96

Metadata

Authors
Cox, A. J., Azeem, A., Yeboah, J., Soliman, E. Z., Aggarwal, S. R., Bertoni, A. G., Carr, J. J., Freedman, B. I., Herrington, D. M., & Bowden, D. W.
Affiliations
Wake Forest University Health Sciences (US)
Corresponding author
Bowden, Donald W.
Venue
Diabetes Care
Published
2014-04-10
Volume
37
Issue
5
Pages
1454-1461
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2154625912
Cited by
96
References
43
Citations by year
2026: 5 · 2025: 2 · 2024: 5 · 2023: 9 · 2022: 9 · 2021: 13 · 2020: 8 · 2019: 5 · 2018: 8 · 2017: 12 · 2016: 8 · 2015: 10 · 2014: 2
FWCI
7.26
Type
journal article
Language
en
Open access
Locations
  • Diabetes Care (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Griffith Research Online (submittedVersion)
Funders
  • National Institutes of Health (5r01ar048797-04)
  • National Heart, Lung, and Blood Institute (F32HL085989, R01HL092301, R01HL067348, T32HL076132)
  • National Institute of Neurological Disorders and Stroke (R01NS058700)
  • National Institute of Arthritis and Musculoskeletal and Skin Diseases (R01-AR48797, R01-AR-048797)
  • National Center for Research Resources (M01RR007122)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes, Cardiovascular Risks, and Lipoproteins
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
Keywords
QTc interval, type 2 diabetes, all-cause mortality, cardiovascular mortality, QTc prolongation, electrocardiogram, prognostic factors
MeSH terms
Cardiac Conduction System Disease, Adult, Arrhythmias, Cardiac, Cardiovascular Diseases, Cause of Death, Diabetes Mellitus, Type 2, Electrocardiography, Female, Heart Conduction System, Heart Rate, Humans, Male, Middle Aged, Prognosis, Risk, Risk Factors, United States, Incidence, Brugada Syndrome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.