Reduced Testing Frequency for Glycated Hemoglobin, HbA1c, Is Associated With Deteriorating Diabetes Control
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We previously showed that in patients with diabetes mellitus, glycated hemoglobin (HbA1c) monitoring outside international guidance on testing frequency is widespread. Here we examined the relationship between testing frequency and diabetes control to test the hypothesis that retest interval is linked to change in HbA1c level. RESEARCH DESIGN AND METHODS: We examined repeat HbA1c tests (400,497 tests in 79,409 patients, 2008–2011) processed by three U.K. clinical laboratories. We examined the relationship between retest interval and 1) percentage change in HbA1c and 2) proportion of cases showing a significant HbA1c rise. The effect of demographics factors on these findings was also explored. RESULTS: Our data showed that the optimal testing frequency required to maximize the downward trajectory in HbA1c was four times per year, particularly in those with an initial HbA1c of ≥7% (≥53 mmol/mol), supporting international guidance. Testing 3-monthly was associated with a 3.8% reduction in HbA1c compared with a 1.5% increase observed with annual testing; testing more frequently provided no additional benefit. Compared with annual monitoring, 3-monthly testing was associated with a halving of the proportion showing a significant rise in HbA1c (7–10 vs. 15–20%). CONCLUSIONS: These findings provide, in a large, multicenter data set, objective evidence that testing outside guidance on HbA1c monitoring frequency is associated with a significant detrimental effect on diabetes control. To achieve the optimum downward trajectory in HbA1c, monitoring frequency should be quarterly, particularly in cases with suboptimal HbA1c. While this impact appears small, optimizing monitoring frequency across the diabetes population may have major implications for diabetes control and comorbidity risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heianza, Y., Arase, Y., Fujihara, K., Hsieh, S. D., Saito, K., Tsuji, H., Kodama, S., Yahagi, N., Shimano, H., Yamada, N., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1793 · Cited by 56
Cited by
DiMeglio, L. A., Acerini, C. L., Codner, E., Craig, M. E., Hofer, S. E., Pillay, K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12737 · Cited by 604
Kebede, M. M., Liedtke, T. P., Möllers, T., & Pischke, C. R. (2017) · Journal of Medical Internet Research · doi:10.2196/jmir.7135 · Cited by 69
Berard, L. D., Siemens, R., & Woo, V. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.007 · Cited by 69
Metadata
- Authors
- Driskell, O. J., Holland, D., Waldron, J. L., Ford, C., Scargill, J. J., Heald, A., Tran, M., Hanna, F. W., Jones, P. W., Pemberton, R. J., & Fryer, A. A.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2014-09-10
- Volume
- 37
- Issue
- 10
- Pages
- 2731-2737
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2017629693
- Cited by
- 75
- References
- 1
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduced Testing Frequency for Glycated Hemoglobin, HbA1c, Is Associated With Deteriorating Diabetes Control. https://app.cochat.ai/papers/10.2337/dc14-0297
- The paper
- Driskell, O. J., Holland, D., Waldron, J. L., Ford, C., Scargill, J. J., Heald, A., Tran, M., Hanna, F. W., Jones, P. W., Pemberton, R. J., & Fryer, A. A. (2014). Reduced Testing Frequency for Glycated Hemoglobin, HbA1c, Is Associated With Deteriorating Diabetes Control. Diabetes Care. https://doi.org/10.2337/dc14-0297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.