CoChat

Comparison of the Pharmacokinetics and Pharmacodynamics of LY2963016 Insulin Glargine and EU- and US-Approved Versions of Lantus Insulin Glargine in Healthy Subjects: Three Randomized Euglycemic Clamp Studies

Linnebjerg, Helle, Lam, Eric Chen Quin, Seger, Mary E., Coutant, David, Chua, Laiyi, Chong, Chew Lan, Ferreira, Maria M., Soon, Danny, Zhang, Xin · 2015 · Diabetes Care
Cited by 94

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: LY2963016 (LY IGlar) and Lantus (IGlar) are insulin glargine products manufactured by distinct processes but with identical amino acid sequences. Three studies evaluated the pharmacokinetic (PK) and pharmacodynamic (PD) similarity of LY IGlar and the European Union– and US-approved versions of IGlar. RESEARCH DESIGN AND METHODS: These were three single-site, randomized, double-blind, two-treatment, four-period, crossover, euglycemic clamp studies. In each study, fasted healthy subjects received 0.5 units/kg s.c. doses of two different insulin glargine products on two occasions each, following a randomized sequence. A ≥7-day washout period separated the doses. Blood samples were collected predose and up to 24 h postdose to assess PK; PD was assessed by a euglycemic clamp lasting up to 24 h. RESULTS: A total of 211 subjects participated in the three studies. The PK (area under the curve [AUC]; maximum observed concentration [Cmax]) and PD (maximum glucose infusion rate [Rmax]; total glucose infusion during the clamp [Gtot]) were similar between LY IGlar and IGlar, with the ratios of geometric means ranging from 0.90 to 0.95 for PK parameters and from 0.91 to 0.99 for PD parameters across studies. In all cases, the 90% CIs for the ratios of geometric means were completely contained in the prespecified acceptance limits of 0.80–1.25. Adverse events were similar between treatments. CONCLUSIONS: These studies demonstrated that the PK and PD properties of LY IGlar and IGlar were similar after single 0.5 units/kg s.c. doses in healthy subjects, contributing to the totality of evidence supporting similarity of these products.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc14-2623

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 94

Metadata

Authors
Linnebjerg, H., Lam, E. C. Q., Seger, M. E., Coutant, D., Chua, L., Chong, C. L., Ferreira, M. M., Soon, D., & Zhang, X.
Venue
Diabetes Care
Published
2015-08-25
Volume
38
Issue
12
Pages
2226-2233
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W1180545115
Cited by
94
References
3
FWCI
11.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the Pharmacokinetics and Pharmacodynamics of LY2963016 Insulin Glargine and EU- and US-Approved Versions of Lantus Insulin Glargine in Healthy Subjects: Three Randomized Euglycemic Clamp Studies. https://app.cochat.ai/papers/10.2337/dc14-2623
The paper
Linnebjerg, H., Lam, E. C. Q., Seger, M. E., Coutant, D., Chua, L., Chong, C. L., Ferreira, M. M., Soon, D., & Zhang, X. (2015). Comparison of the Pharmacokinetics and Pharmacodynamics of LY2963016 Insulin Glargine and EU- and US-Approved Versions of Lantus Insulin Glargine in Healthy Subjects: Three Randomized Euglycemic Clamp Studies. Diabetes Care. https://doi.org/10.2337/dc14-2623

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.