The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.
One Year Clinical Experience of the First Commercial Hybrid Closed-Loop System
Open accessAbstract
OBJECTIVE: In September 2016, the U.S. Food and Drug Administration approved the Medtronic 670G “hybrid” closed-loop system. In Auto Mode, this system automatically controls basal insulin delivery based on continuous glucose monitoring data but requires users to enter carbohydrates and blood glucose for boluses. To track real-world experience with this first commercial closed-loop device, we prospectively followed pediatric and adult patients starting the 670G system. RESEARCH DESIGN AND METHODS: This was a 1-year prospective observational study of patients with type 1 diabetes starting the 670G system between May 2017 and May 2018 in clinic. RESULTS: Of the total of 84 patients who received 670G and consented, 5 never returned for follow-up, with 79 (aged 9–61 years) providing data at 1 week and 3, 6, 9, and/or 12 months after Auto Mode initiation. For the 86% (68 out of 79) with 1-week data, 99% (67 out of 68) successfully started. By 3 months, at least 28% (22 out of 79) had stopped using Auto Mode; at 6 months, 34% (27 out of 79); at 9 months, 35% (28 out of 79); and by 12 months, 33% (26 out of 79). The primary reason for continuing Auto Mode was desire for increased time in range. Reasons for discontinuation included sensor issues in 62% (16 out of 26), problems obtaining supplies in 12% (3 out of 26), hypoglycemia fear in 12% (3 out of 26), multiple daily injection preference in 8% (2 out of 26), and sports in 8% (2 out of 26). At all visits, there was a significant correlation between hemoglobin A1c (HbA1c) and Auto Mode utilization. CONCLUSIONS: While Auto Mode utilization correlates with improved glycemic control, a focus on usability and human factors is necessary to ensure use of Auto Mode. Alarms and sensor calibration are a major patient concern, which future technology should alleviate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“with consistent improvement in A1C, increase in TIR, especially overnight, as well as reduction of time spent in hypoglycemia (207-219).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [210]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“all AID system pivotal trials that examined individuals 2 years old or older, including older adults, have consistently demonstrated superiority to either standard insulin delivery (or manual mode for the single-arm studies) or SAP and/or usual care (for the randomized trials)”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [210]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“with consistent improvement in A1C, increase in TIR, especially overnight, as well as reduction of time spent in hypoglycemia (207-219).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [210]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“with consistent improvement in A1C, increase in TIR, especially overnight, as well as reduction of time spent in hypoglycemia (207-219).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [210]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harris, P. A., Taylor, R., Thielke, R., Payne, J., Gonzalez, N., & Conde, J. G. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.08.010 · Cited by 51,384 · cited 7×
“The REDCap platform services are made possible by the Stanford University School of Medicine Research Office.”
MethodInfluential(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
The Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications (EDIC) Study Research Group (2016) · Diabetes Care · doi:10.2337/dc15-1990 · Cited by 712
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644 · cited 2×
“Middle Eastern 3 (4) 0 (0) 3 (6) Native American 1 (1) 1 (4) 0 (0)”
Self-citationGarg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585 · cited 3×
“Prior insulin delivery systems Animas 13 (9) 3 (8) 10 (10) Medtronic, older 62 (45) 19 (49) 43 (44) Medtronic 630G 37 (27) 13 (33) 24 (24) Omnipod 5 (4) 1 (3) 4 (4) Roche 1 (1) 0 (0) 1 (1) Tandem 4 (3) 0 (0) 4 (4) Multiple daily injections 4 (3) 1 (3) 3 (3) Other 11 (8) 2 (5) 9 (9)”
Self-citationTauschmann, M., Thabit, H., Bally, L., Allen, J. M., Hartnell, S., Wilinska, M. E., Ruan, Y., Sibayan, J., Kollman, C., Cheng, P., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31947-0 · Cited by 440
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Self-citationSafety Evaluation of the MiniMed 670G System in Children 7–13 Years of Age with Type 1 Diabetes
Forlenza, G. P., Pinhas-Hamiel, O., Liljenquist, D. R., Shulman, D. I., Bailey, T. S., Bode, B. W., Wood, M. A., Buckingham, B. A., Kaiserman, K. B., Shin, J., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0264 · Cited by 182
Self-citation7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
Abraham, M. B., Nicholas, J. A., Smith, G. J., Fairchild, J. M., King, B. R., Ambler, G. R., Cameron, F. J., Davis, E. A., Jones, T. W., & on behalf of the PLGM Study Group (2017) · Diabetes Care · doi:10.2337/dc17-1604 · Cited by 144
Cited by
A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Self-citationPhillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citation7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Self-citationBergenstal, R. M., Nimri, R., Beck, R. W., Criego, A., Laffel, L., Schatz, D., Battelino, T., Danne, T., Weinzimer, S. A., Sibayan, J., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32514-9 · Cited by 344
Self-citation
Metadata
- Authors
- Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M.
- Affiliations
- Stanford Medicine (US)
- Corresponding author
- Lal, Rayhan A.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2019-09-23
- Volume
- 42
- Issue
- 12
- Pages
- 2190-2196
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC6868462
- OpenAlex
- W2976192468
- Cited by
- 215
- References
- 29
- Citations by year
- 2026: 5 · 2025: 15 · 2024: 25 · 2023: 35 · 2022: 36 · 2021: 62 · 2020: 33 · 2019: 4
- FWCI
- 27.40
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Diabetes Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (UL1-TR-001085, P30-DK-116074, 1K12-DK-122550)
- National Institute for Diabetes and Digestive and Kidney Diseases (T32-DK-007217, 1K12-DK-122550)
- NIH (DP3-DK-104059, DP3-DK-101055, DK-14024)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- hybrid closed-loop system, type 1 diabetes, continuous glucose monitoring, device utilization, hypoglycemia, sensor calibration, glycemic control, HbA1c, usability, human factors, time in range
- MeSH terms
- Adolescent, Adult, Blood Glucose, Child, Diabetes Mellitus, Type 1, Equipment Design, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Middle Aged, Prospective Studies, United States, Blood Glucose Self-Monitoring, Treatment Outcome, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One Year Clinical Experience of the First Commercial Hybrid Closed-Loop System. https://app.cochat.ai/papers/10.2337/dc19-0855
- The paper
- Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019). One Year Clinical Experience of the First Commercial Hybrid Closed-Loop System. Diabetes Care. https://doi.org/10.2337/dc19-0855
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.