The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Six Months of Hybrid Closed-Loop Versus Manual Insulin Delivery With Fingerprick Blood Glucose Monitoring in Adults With Type 1 Diabetes: A Randomized, Controlled Trial
Open accessAbstract
Objective To investigate glycemic and psychosocial outcomes with hybrid closed-loop (HCL) versus user-determined insulin dosing with multiple daily injections (MDI) or insulin pump (i.e., standard therapy for most adults with type 1 diabetes). Research design and methods Adults with type 1 diabetes using MDI or insulin pump without continuous glucose monitoring (CGM) were randomized to 26 weeks of HCL (Medtronic 670G) or continuation of current therapy. The primary outcome was masked CGM time in range (TIR; 70-180 mg/dL) during the final 3 weeks. Results Participants were randomized to HCL ( n = 61) or control ( n = 59). Baseline mean (SD) age was 44.2 (11.7) years, HbA 1c was 7.4% (0.9%) (57 [10] mmol/mol), 53% were women, and 51% used MDI. HCL TIR increased from (baseline) 55% (13%) to (26 weeks) 70% (10%) with the control group unchanged: (baseline) 55% (12%) and (26 weeks) 55% (13%) (difference 15% [95% CI 11, 19]; P 1c was lower (median [95% CI] difference -0.4% [-0.6, -0.2]; -4 mmol/mol [-7, -2]; P P Conclusions In adults with type 1 diabetes, 26 weeks of HCL improved TIR, HbA 1c , and their sense of satisfaction from managing their diabetes compared with those continuing with user-determined insulin dosing and self-monitoring of blood glucose. For most people living with type 1 diabetes globally, this trial demonstrates that HCL is feasible, acceptable, and advantageous.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Both generation 1 low-glucose-suspend33 and generation 2 hybrid closed-loop systems improve glycated haemoglobin concentrations, the time in target range and the time below target range in children, adolescents34 and adults.35-37”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [35]
Citations
Cites
State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Nathan, D. M., & for the DCCT/EDIC Research Group (2014) · Diabetes Care · doi:10.2337/dc13-2112 · Cited by 1,832
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644
International Hypoglycaemia Study Group (2017) · Diabetes Care · doi:10.2337/dc16-2215 · Cited by 608
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Weisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463
The T1D exchange clinic registry
Beck, R. W., Tamborlane, W. V., Bergenstal, R. M., Miller, K. M., DuBose, S. N., Hall, C. A., & for the T1D Exchange Clinic Network (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1561 · Cited by 456
Cited by
Sorted by citations
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citationAbraham, M. B., de Bock, M. I., Smith, G. J., Dart, J., Fairchild, J. M., King, B. R., Ambler, G. R., Cameron, F. J., McAuley, S. A., KEECH, A. C., et al. (2021) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2021.3965 · Cited by 128
Self-citationA Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
McAuley, S. A., Trawley, S., Vogrin, S., Ward, G. M., Fourlanos, S., Grills, C. A., Lee, M. H., Alipoor, A. M., O’Neal, D. N., O’Regan, N. A., et al. (2022) · Diabetes Care · doi:10.2337/dc21-1667 · Cited by 117
Self-citationCurrent Advances of Artificial Pancreas Systems: A Comprehensive Review of the Clinical Evidence
Moon, S. J., Jung, I., & Park, C. (2021) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2021.0177 · Cited by 109
Metadata
- Authors
- McAuley, S. A., Lee, M. H., Paldus, B., Vogrin, S., de Bock, M. I., Abraham, M. B., Bach, L. A., Burt, M. G., Cohen, N. D., Colman, P. G., Davis, E. A., Hendrieckx, C., Holmes-Walker, D. J., Kaye, J., Keech, A. C., Kumareswaran, K., MacIsaac, R. J., McCallum, R. W., Sims, C. M., Speight, J., Stranks, S. N., Sundararajan, V., Trawley, S., Ward, G. M., Jenkins, A. J., Jones, T. W., O’Neal, D. N., Australian JDRF Closed-Loop Research Group, O’Neal, D. N., McAuley, S. A., Lee, M. H., Paldus, B., Sims, C. M., MacIsaac, R. J., Ward, G. M., Colman, P. G., Cohen, N. D., Bach, L. A., Kumareswaran, K., Stranks, S. N., Burt, M. G., Holmes-Walker, D. J., McCallum, R. W., Kaye, J., Speight, J., Hendrieckx, C., Halliday, J., Russell-Green, S., Trawley, S., Jenkins, A. J., Januszewski, A., Keech, A. C., Vogrin, S., Sundararajan, V., Mohammed Husin, H., Clarke, P. M., Jones, T. W., Davis, E. A., de Bock, M. I., Abraham, M. B., Ambler, G. R., Cameron, F. J., Fairchild, J. M., & King, B. R.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2020-10-14
- Volume
- 43
- Issue
- 12
- Pages
- 3024-3033
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W3092965120
- Cited by
- 158
- References
- 38
- Citations by year
- 2026: 17 · 2025: 24 · 2024: 33 · 2023: 37 · 2022: 30 · 2021: 16 · 2020: 1
- FWCI
- 15.84
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Deakin Research Online (Deakin University) (submittedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Funders
- JDRF Australian Type 1 Diabetes Clinical Research Network (3-SRA-2016-351-M-B)
- National Health and Medical Research Council of Australia (APP1099379)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- type 1 diabetes, hybrid closed-loop insulin delivery, insulin pump therapy, multiple daily insulin injections, continuous glucose monitoring, time in range, glycemic control, HbA1c, diabetes distress, sleep quality, cognitive function, device-related adverse events, adults with type 1 diabetes, diabetes self-management
- MeSH terms
- Adult, Aged, Blood Glucose, Blood Specimen Collection, Diabetes Mellitus, Type 1, Female, Fingers, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Injections, Insulin, Insulin Infusion Systems, Male, Middle Aged, Personal Satisfaction, Blood Glucose Self-Monitoring, Needlestick Injuries
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review