Extended Use of the Control-IQ Closed-Loop Control System in Children With Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To further evaluate the safety and efficacy of the Control-IQ closed-loop control (CLC) system in children with type 1 diabetes. RESEARCH DESIGN AND METHODS: After a 16-week randomized clinical trial (RCT) comparing CLC with sensor-augmented pump (SAP) therapy in 101 children 6–13 years old with type 1 diabetes, 22 participants in the SAP group initiated use of the CLC system (referred to as SAP-CLC cohort), and 78 participants in the CLC group continued use of CLC (CLC-CLC cohort) for 12 weeks. RESULTS: In the SAP-CLC cohort, mean percentage of time in range 70–180 mg/dL (TIR) increased from 55 ± 13% using SAP during the RCT to 65 ± 10% using CLC (P < 0.001), with 36% of the cohort achieving TIR >70% plus time <54 mg/dL <1% compared with 14% when using SAP (P = 0.03). Substantial improvement in TIR was seen after the 1st day of CLC. Time <70 mg/dL decreased from 1.80% to 1.34% (P < 0.001). In the CLC-CLC cohort, mean TIR increased from 53 ± 17% prerandomization to 67 ± 10% during the RCT and remained reasonably stable at 66 ± 10% through the 12 weeks post-RCT. No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either cohort. CONCLUSIONS: This further evaluation of the Control-IQ CLC system supports the findings of the preceding RCT that use of a closed-loop system can safely improve glycemic control in children 6–13 years old with type 1 diabetes from the 1st day of use and demonstrates that these improvements can be sustained through 28 weeks of use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482 · cited 1×
“P values are two-sidedandhavebeenadjusted for multiple comparisons to control the false discovery rate using the adaptive Benjamini-Hochberg procedure (4).”
MethodBattelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“However, this change, although statistically significant, is far below the threshold of 5% to be considered clinically meaningful (5).”
BackgroundSelf-citationSix-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030 · cited 11×
“The percentagesof participantswithHbA1c,7.5% were 45%, 74%, and 63%, respectively (Supplementary Table 6).”
BackgroundSelf-citationA Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Self-citationHome Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450 · cited 2×
“70% plus time ,70 mg/dL ,4% 2 (9) 3 (14) 8 (36) NA 0.”
ResultSelf-citation
Cited by
One Year Real-World Use of the Control-IQ Advanced Hybrid Closed-Loop Technology
Breton, M. D., & Kovatchev, B. P. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0097 · Cited by 250
“Both RCTs had extension studies (total of 6 months use for pediatric and 18 months for adults) that showed maintenance of this improvement: +9 and +10 percentage points for adolescents/adults and children, respectively.(21,22) Exposure to hypoglycemia remained low throughout our analysis period with median time below…”
ResultSelf-citationA Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Van Name, M. A., Kanapka, L. G., DiMeglio, L. A., Miller, K. M., Albanese-O’Neill, A., Commissariat, P., Corathers, S. D., Harrington, K. R., Hilliard, M. E., Anderson, B. J., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221084667 · Cited by 20
Self-citation
Metadata
- Authors
- Kanapka, L. G., Wadwa, R. P., Breton, M. D., Ruedy, K. J., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M. J., Jost, E., Carria, L., Emory, E., Hsu, L. J., Weinzimer, S. A., DeBoer, M. D., Buckingham, B. A., Oliveri, M., Kollman, C., Dokken, B. B., Cherñavvsky, D., & Beck, R. W.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2021-01-13
- Volume
- 44
- Issue
- 2
- Pages
- 473-478
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W3117663092
- Cited by
- 56
- References
- 5
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extended Use of the Control-IQ Closed-Loop Control System in Children With Type 1 Diabetes. https://app.cochat.ai/papers/10.2337/dc20-1729
- The paper
- Kanapka, L. G., Wadwa, R. P., Breton, M. D., Ruedy, K. J., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M. J., Jost, E., Carria, L., Emory, E., Hsu, L. J., Weinzimer, S. A., DeBoer, M. D., Buckingham, B. A., Oliveri, M., Kollman, C., Dokken, B. B., Cherñavvsky, D., & Beck, R. W. (2021). Extended Use of the Control-IQ Closed-Loop Control System in Children With Type 1 Diabetes. Diabetes Care. https://doi.org/10.2337/dc20-1729
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.