CoChat

Interferent Effect of Hydroxyurea on Continuous Glucose Monitoring

Szmuilowicz, Emily D., Aleppo, Grazia · 2021 · Diabetes Care

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

While currently available continuous glucose monitoring (CGM) systems have continually improving accuracy that has revolutionized modern diabetes care, potential medication interferences are recognized for all available CGM systems (1). For Dexcom CGM systems, hydroxyurea was recently recognized as an interfering substance that can falsely elevate sensor glucose (SG) readings (2), but the data demonstrating this interference have not been previously published. We report a patient with type 1 diabetes taking hydroxyurea who experienced falsely elevated SG values using the Dexcom G5 and G6 CGM systems, which led to the recognition of the interferent effect of hydroxyurea. A 69-year-old woman with type 1 diabetes using an insulin pump (Medtronic Paradigm Revel 723) and real-time CGM (initially Dexcom G5, then G6) took hydroxyurea (1,000 mg daily) for treatment of essential thrombocytosis. She noted that, for approximately 6 h after taking hydroxyurea, SG measurements predictably and markedly increased, even while fasting and when the time of hydroxyurea ingestion varied. In addition, the glucose management indicator (7.6%) based on 14-day average SG (170 mg/dL) was significantly higher than concomitant glycated hemoglobin (6.3%, 45 mmol/mol), suggestive of artifactual discordance. Subsequently, the patient simultaneously wore the Dexcom G6 …

Overview

Integrity signals

Registry

Crossref · 10.2337/dc20-3114

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 23

Metadata

Authors
Szmuilowicz, E. D., & Aleppo, G.
Affiliations
Northwestern University (US)
Corresponding author
Szmuilowicz, Emily D.
Venue
Diabetes Care
Published
2021-03-02
Volume
44
Issue
5
Pages
e89-e90
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W3135189747
Cited by
23
References
3
Citations by year
2026: 4 · 2025: 6 · 2024: 4 · 2023: 6 · 2022: 2 · 2021: 1
FWCI
2.43
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Care (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
Keywords
hydroxyurea, continuous glucose monitoring, sensor interference, Dexcom G6, type 1 diabetes, essential thrombocythemia, insulin pump, glucose management indicator
MeSH terms
Blood Glucose, Humans, Hydroxyurea, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.