Simplified meal announcement versus precise carbohydrate counting in adolescents with type 1 diabetes using the MiniMed 780G advanced hybrid closed loop system: a randomized controlled trial comparing glucose control
Open accessAbstract
OBJECTIVE: We aimed to compare glucose control in adolescents with type 1 diabetes (T1D) using the MiniMed 780G system who used simplified meal announcement with those who used precise carbohydrate counting. RESEARCH DESIGN AND METHODS: This randomized controlled trial included 34 participants (age 12–18 years) with T1D who were on multiple daily injections or insulin pump and were scheduled to start using the MiniMed 780G system at Sidra Medicine in Qatar. After a 7-day run-in period, participants were randomly assigned to the fix group (simplified meal announcement by preset of three personalized fixed carbohydrate amounts) or the flex group (precise carbohydrate counting) and followed for 12 weeks. Between-group difference in time in range (TIR) was the primary end point. Secondary end points included HbA1c and other glycometrics. RESULTS: During the 12-week study phase, TIR was 73.5 ± 6.7% in the fix and 80.3 ± 7.4% in the flex group, with a between-group difference of 6.8% in favor of flex (P = 0.043). Time >250 mg/dL was better in the flex group (P = 0.012), whereas HbA1c (P = 0.168), time below range (P = 0.283), and time between 180 and 250 mg/dL (P = 0.114) did not differ. CONCLUSIONS: Adolescents using the MiniMed 780G system with a preset of three personalized fixed carbohydrate amounts can reach international targets of glycemic control. Therefore, it may be a valuable alternative to precise carbohydrate counting in users who are challenged by precise carbohydrate counting. Because carbohydrate counting further improves outcomes, these skills remain important for MiniMed 780G users.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
With some AID systems, use of a simplified meal announcement method may be an alternative for prandial insulin dosing.
“With some AID systems, use of a simplified meal announcement method may be an alternative for prandial insulin dosing (31,63).”
From 9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2025 (2025) · cites this paper as [63]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,032 · see citing works
Bergenstal, R. M., Nimri, R., Beck, R. W., Criego, A., Laffel, L., Schatz, D., Battelino, T., Danne, T., Weinzimer, S. A., Sibayan, J., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32514-9 · Cited by 344 · see citing works
One Year Real-World Use of the Control-IQ Advanced Hybrid Closed-Loop Technology
Breton, M. D., & Kovatchev, B. P. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0097 · Cited by 250 · see citing works
Carlson, A. L., Sherr, J. L., Shulman, D. I., Garg, S. K., Pop-Busui, R., Bode, B. W., Lilenquist, D. R., Brazg, R. L., Kaiserman, K. B., Kipnes, M. S., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0319 · Cited by 230 · see citing works
Real-World Performance of the MiniMed™ 780G System: First Report of Outcomes from 4120 Users
Silva, J. D., Lepore, G., Battelino, T., Arrieta, A., Castañeda, J., Grossman, B., Shin, J., & Cohen, O. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0203 · Cited by 229 · see citing works
Lenters-Westra, E., & Slingerland, R. J. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.130641 · Cited by 228 · see citing works
Efficacy of carbohydrate counting in type 1 diabetes: A systematic review and meta-analysis
Bell, K. J., Barclay, A. W., Petocz, P., Colagiuri, S., & Brand-Miller, J. C. (2014) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(13)70144-x · Cited by 213 · see citing works
Flagged first, then by citations
Research works printed but not linked: 13
- [1]Mehta SN, Quinn N, Volkening LK, Laffel LM. Impact of carbohydrate counting on glycemic control in children with type 1 diabetes. Diabetes Care 2009; 32: 1014– 1016 19244089 PMC2681033
- [2]Brazeau AS, Mircescu H, Desjardins K,. Carbohydrate counting accuracy and blood glucose variability in adults with type 1 diabetes. Diabetes Res Clin Pract 2013; 99: 19– 23 23146371
- [3]Builes-Montaño CE, Ortiz-Cano NA, Ramirez-Rincón A, Rojas-Henao NA. Efficacy and safety of carbohydrate counting versus other forms of dietary advice in patients with type 1 diabetes mellitus: a systematic review and meta-analysis of randomised clinical trials. J Hum Nutr Diet 2022; 35: 1030– 1042 35436364
- [5]Ruan Y, Thabit H, Leelarathna L,.; AP@home Consortium. Variability of insulin requirements over 12 weeks of closed-loop insulin delivery in adults with type 1 diabetes. Diabetes Care 2016; 39: 830– 832 26965717
- [7]Isganaitis E, Raghinaru D, Ambler-Osborn L,.; iDCL Trial Research Group. Closed-loop insulin therapy improves glycemic control in adolescents and young adults: outcomes from the International Diabetes Closed-Loop Trial. Diabetes Technol Ther 2021; 23: 342– 349 33216667 PMC8080922
- [10]Petrovski G, Al Khalaf F, Campbell J,. Successful transitioning children and adolescents with type 1 diabetes from multiple daily injections to advanced hybrid closed-loop system in 10 days: a prospective intervention study on MiniMed 780G system. Acta Diabetol 2022; 59: 743– 746 35072781
- [11]Beato-Víbora PI, Gallego-Gamero F, Ambrojo-López A, Gil-Poch E, Martín-Romo I, Arroyo-Díez FJ. Rapid improvement in time in range after the implementation of an advanced hybrid closed-loop system in adolescents and adults with type 1 diabetes. Diabetes Technol Ther 2021; 23: 609– 615 33784187
- [12]Petrovski G, Al Khalaf F, Campbell J, Fisher H, Umer F, Hussain K. 10-Day structured initiation protocol from multiple daily injection to hybrid closed-loop system in children and adolescents with type 1 diabetes. Acta Diabetol 2020; 57: 681– 687 31953687 PMC7220973
- [13]Arrieta A, Battelino T, Scaramuzza AE,. Comparison of MiniMed 780G system performance in users aged younger and older than 15 years: evidence from 12 870 real-world users. Diabetes Obes Metab 2022; 24: 1370– 1379 35403792 PMC9545031
- [15]Tornese G, Carletti C, Giangreco M, Nisticò D, Faleschini E, Barbi E. Carbohydrate tolerance threshold for unannounced snacks in children and adolescents with type 1 diabetes using an advanced hybrid closed-loop system. Diabetes Care 2022; 45: 1486– 1488 35522033 PMC9210515
- [16]Smart CE, Annan F, Higgins LA, Jelleryd E, Lopez M, Acerini CL. ISPAD clinical practice consensus guidelines 2018: nutritional management in children and adolescents with diabetes. Pediatr Diabetes 2018; 19(Suppl. 27): 136– 154 30062718
- [18]Castañeda J, Mathieu C, Aanstoot HJ,. Predictors of time in target glucose range in real-world users of the MiniMed 780G system. Diabetes Obes Metab 2022; 24: 2212– 2221 35791621
- [19]Abildgaard A, Knudsen CS, Bjerg LN, Lund S, Støy J. Lot variation and inter-device differences contribute to poor analytical performance of the DCA Vantage™ HbA1c POCT instrument in a true clinical setting. Clin Chem Lab Med 2021; 60: 127– 134 34480844
Cited by
Sorted by citations
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Bajaj, M., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s009 · Cited by 728 · see citing works
- Authors
- Petrovski, G., Campbell, J., Pasha, M., Day, E., Hussain, K., Khalifa, A., & van den Heuvel, T.
- Affiliations
- Sidra Medical and Research Center (QA)
- 2Medtronic International Trading Sàrl, Tolochenaz, Switzerland
- Corresponding author
- Petrovski, Goran
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2023-01-04
- Volume
- 46
- Issue
- 3
- Pages
- 544-550
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC10148675
- OpenAlex
- W4313483851
- Cited by
- 108
- References
- 7
- Citations by year
- 2026: 25 · 2025: 33 · 2024: 33 · 2023: 17
- FWCI
- 22.16
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Diabetes Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Sanofi
- Dexcom
- Sidra Medicine
- Novo Nordisk
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- type 1 diabetes, adolescents, MiniMed 780G, hybrid closed-loop system, carbohydrate counting, glycemic control, time in range, HbA1c, insulin pump therapy
- MeSH terms
- Adolescent, Blood Glucose, Child, Diabetes Mellitus, Type 1, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review