Cited by 230Diabetes Management and ResearchDiabetes Management and EducationDiabetes and associated disorders

Safety and Glycemic Outcomes During the MiniMed™ Advanced Hybrid Closed-Loop System Pivotal Trial in Adolescents and Adults with Type 1 Diabetes

Open access
Carlson, Anders L., Sherr, Jennifer L., Shulman, Dorothy I., Garg, Satish K., Pop-Busui, Rodica, Bode, Bruce W., Lilenquist, David R., Brazg, Ron L. +18 more·2022·Diabetes Technology & Therapeutics

Abstract

Introduction: This trial assessed safety and effectiveness of an advanced hybrid closed-loop (AHCL) system with automated basal (Auto Basal) and automated bolus correction (Auto Correction) in adolescents and adults with type 1 diabetes (T1D). Materials and Methods: This multicenter single-arm study involved an intent-to-treat population of 157 individuals (39 adolescents aged 14–21 years and 118 adults aged ≥22–75 years) with T1D. Study participants used the MiniMed™ AHCL system during a baseline run-in period in which sensor-augmented pump +/− predictive low glucose management or Auto Basal was enabled for ∼14 days. Thereafter, Auto Basal and Auto Correction were enabled for a study phase (∼90 days), with glucose target set to 100 or 120 mg/dL for ∼45 days, followed by the other target for ∼45 days. Study endpoints included safety events and change in mean A1C, time in range (TIR, 70–180 mg/dL) and time below range (TBR, <70 mg/dL). Run-in and study phase values were compared using Wilcoxon signed-rank test or paired t -test. Results: Overall group time spent in closed loop averaged 94.9% ± 5.4% and involved only 1.2 ± 0.8 exits per week. Compared with run-in, AHCL reduced A1C from 7.5% ± 0.8% to 7.0% ± 0.5% (<0.001, Wilcoxon signed-rank test, n = 155), TIR increased from 68.8% ± 10.5% to 74.5% ± 6.9% (<0.001, Wilcoxon signed-rank test), and TBR reduced from 3.3% ± 2.9% to 2.3% ± 1.7% (<0.001, Wilcoxon signed-rank test). Similar benefits to glycemia were observed for each age group and were more pronounced for the nighttime (12 AM–6 AM). The 100 mg/dL target increased TIR to 75.4% ( n = 155), which was further optimized at a lower active insulin time (AIT) setting (i.e., 2 h), without increasing TBR. There were no severe hypoglycemic or diabetic ketoacidosis events during the study phase. Conclusions: These findings show that the MiniMed AHCL system is safe and allows for achievement of recommended glycemic targets in adolescents and adults with T1D. Adjustments in target and AIT settings may further optimize glycemia and improve user experience. Clinical Trial Registration number: NCT03959423.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2021.0319

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Carlson, A. L., Sherr, J. L., Shulman, D. I., Garg, S. K., Pop-Busui, R., Bode, B. W., Lilenquist, D. R., Brazg, R. L., Kaiserman, K. B., Kipnes, M. S., Thrasher, J. R., Reed, J. H. C., Slover, R. H., Philis-Tsimikas, A., Christiansen, M., Grosman, B., Roy, A., Vella, M., Jonkers, R. A. M., Chen, X., Shin, J., Cordero, T. L., Lee, S. W., Rhinehart, A. S., Vigersky, R. A., & for the MiniMed™ AHCL Study Group
Affiliations
  • HealthPartners (US)
  • Yale University (US)
  • University of South Florida (US)
  • Barbara Davis Center of Childhood Diabetes, Aurora, Colorado, USA.
  • Division of Metabolism, Endocrinology and Diabetes, University of Michigan, Ann Arbor, Michigan, USA.
  • Atlanta Diabetes Associates (US)
  • Rocky Mountain Diabetes and Osteoporosis Center, Idaho Falls, Idaho, USA.
  • Rainier Clinical Research Center, Renton, Washington, USA.
  • SoCal Diabetes, Torrance, California, USA.
  • Diabetes & Glandular Disease Clinic (US)
  • Arkansas Diabetes and Endocrinology Center, Little Rock, Arkansas, USA.
  • Endocrine Research Solutions (United States) (US)
  • Scripps Whittier Diabetes Institute, La Jolla, California, USA.
  • Diablo Clinical Research (US)
  • Medtronic (United States) (US)
Corresponding author
Carlson, Anders L.
Venue
Diabetes Technology & Therapeutics
Published
2022-03
Volume
24
Issue
3
Pages
178-189
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W3210094726
Cited by
230
References
43
Citations by year
2026: 35 · 2025: 45 · 2024: 55 · 2023: 61 · 2022: 34
FWCI
28.00
Type
journal article
Language
en
Open access
Locations
  • Diabetes Technology & Therapeutics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (P30DK020572, P30DK045735, P30DK111022)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
Keywords
type 1 diabetes, hybrid closed-loop system, glycemic control, HbA1c, time in range, time below range, sensor-augmented pump, adolescents, adults, clinical trial safety, glycemic outcomes
MeSH terms
Adolescent, Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Middle Aged, Blood Glucose Self-Monitoring, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review