CoChat

Levels of Plasma Insulin During Cortisone Glucose Tolerance Tests in “Nondiabetic” Relatives of Diabetic Patients: Implications of Diminished Insulin Secretory Reserve in Subclinical Diabetes

Rull, Juan A, Conn, J W, Floyd, John C, Fajans, Stefan S · 1970 · Diabetes
Cited by 48

The DOI matches its Crossref record.

Abstract

Plasma levels of insulin were determined during standard oral glucose tolerance tests and during cortisone glucose tolerance tests performed upon “nondiabetic” subjects (normal standard GTT) who were first degree relatives of diabetic patients. The standard test was also performed upon mildly diabetic patients and healthy control subjects. The results of the standard glucose tolerance test (levels of plasma insulin and blood glucose) did not differentiate the relatives with positive cortisone glucose tolerance tests (subclinical diabetes) from those with negative cortisone glucose tolerance tests although in both groups levels of plasma insulin were lower than in healthy subjects. However, the results of the cortisone glucose tolerance test did distinguish the group with subclinical diabetes from the relatives with negative tests since the secretion of insulin was delayed and insufficient in the subjects with positive testsl During the standard test patients with mild “maturityonset” diabetes showed delayed and insufficient secretion of insulin as compared to the healthy subjects. It is concluded that during the cortisone glucose tolerance test, “nondiabetic” relatives of diabetic patients who have positive tests (subclinical diabetes) exhibit a defect in the secretion of insulin which distinguishes them from subjects with negative tests. This defect is similar in pattern to that observed in mildly diabetic patients during the standard test. This deficiency in the secretion of insulin represents an important part of the mechanism which induces a positive cortisone glucose tolerance test. This demonstration that, in some relatives of diabetics, a grossly normal standard glucose tolerance can exist at a time when decreased reserve insulin secretory capacity can be measured, justifies a careful evaluation of whether some form of therapy is indicated at this stage of the disease (subclinical diabetes) and, if so, what form it should be. The meaning of the statistically significant subnormal response of plasma insulin to a standard glucose load in relatives with negative cortisone glucose tests is not yet apparent. Since in them the reserve insulin secretory capacity, as measured by the CGTT, remains intact, it is premature, pending additional data, to raise the question of possible treatment of this group.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diab.19.1.1

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 48

Metadata

Authors
Rull, J. A., Conn, J. W., Floyd, J. C., & Fajans, S. S.
Venue
Diabetes
Published
1970-01-01
Volume
19
Issue
1
Pages
1-10
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2335411753
Cited by
48
References
0
FWCI
15.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Levels of Plasma Insulin During Cortisone Glucose Tolerance Tests in “Nondiabetic” Relatives of Diabetic Patients: Implications of Diminished Insulin Secretory Reserve in Subclinical Diabetes. https://app.cochat.ai/papers/10.2337/diab.19.1.1
The paper
Rull, J. A., Conn, J. W., Floyd, J. C., & Fajans, S. S. (1970). Levels of Plasma Insulin During Cortisone Glucose Tolerance Tests in “Nondiabetic” Relatives of Diabetic Patients: Implications of Diminished Insulin Secretory Reserve in Subclinical Diabetes. Diabetes. https://doi.org/10.2337/diab.19.1.1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.