Plasma Insulin and Glucose Responses of Healthy Subjects to Varying Glucose Loads During Three-hour Oral Glucose Tolerance Tests
The DOI matches its Crossref record.
Abstract
The plasma glucose and plasma immunoreactive insulin concentrations of twelve healthy, nonobese, adult subjects were compared following administration of oral glucose loads of 50, 75 and 100 gm., and 1.75 gm./kg. body weight. The time of occurrence and the magnitude of maximal plasma glucose and insulin concentrations were unaffected by the 25 gm. increases in glucose load. The 50 gm. glucose load gave the smallest plasma glucose response during the three-hour tests and this response was statistically distinguishable from the plasma glucose responses due to the 100 gm. and 1.75 gm./kg. loads (p < 0.05). The plasma glucose responses due to the other loads did not differ from each other. Insulin responses, estimated by either summing allthe plasma insulin values or by measuring the areas under the curves, increased approximately 35 per cent with the first 25 gm. glucose load increment (50 to 75 gm.) and 27 per cent with the second 25 gm. load increment (75 to 100 gm.) during the three-hour study. The differences in insulinresponses between the 50 gm. load and the 100 gm. or 1.75 gm./kg. loads were highly significant (p < 0.01) while the difference between the insulin responses following the 75 gm. and 1.75 gm./kg. loads had lower significance (p < 0.05). Differences in insulin responses of the other loads were not significant. Increases in glucose loads above 120 gm. did not further increase the insulin response. This provides evidence that maximal insulin responses provoked by an oral glycemic stimulus alone in subjects are achieved with 100 gm. A wide range was observed in the plasma insulin concentrations among these healthy individuals for any given load, at any one time, and was probably due to biological variation. The fact that incremental changes in glucose load particularly influenced plasma glucose and insulin concentrations relatively late in the glucose tolerance tests, and that mean insulin peakconcentrations did not differ, indicates that increasing glucose load results in a more prolongedinsulinogenic stimulus rather than the acute release of greater quantities of insulin relatively abruptly. These studies provide evidence that the response associated with increasing glucose load is to some extent a function of the quantity of glucose ingested, and that the significant increases in insulin response commonly occur in association with concurrent alterations in plasma glucose concentrations. The results also indicate that the 50 gm. glucose load results in a different plasma glucose response than does the 100 gm. and 1.75 gm./kg. loads and consequently requires different criteria for interpretation of glucose tolerance testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
NAUCK, M. A., HOMBERGER, E., SIEGEL, E. G., ALLEN, R. C., EATON, R. P., EBERT, R., & CREUTZFELDT, W. (1986) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-63-2-492 · Cited by 874
Peters, A. L. (1996) · JAMA · doi:10.1001/jama.1996.03540150048030 · Cited by 303
Plasma glucose and insulin response to macronutrients in nondiabetic and NIDDM subjects
Nuttall, F. Q., & Gannon, M. C. (1991) · Diabetes Care · doi:10.2337/diacare.14.9.824 · Cited by 152
Effect of Glycemia on Plasma Incretins and the Incretin Effect During Oral Glucose Tolerance Test
Salehi, M., Aulinger, B., & D’Alessio, D. A. (2012) · Diabetes · doi:10.2337/db11-1825 · Cited by 38
“Subjects were studied with an oral glucose tolerance test (OGTT) during a hyperglycemic clamp (11).”
MethodInfluentialThe incretin effect in obese adolescents with and without type 2 diabetes: impaired or intact?
Aulinger, B. A., Vahl, T. P., Prigeon, R. L., D'Alessio, D. A., & Elder, D. A. (2016) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00496.2015 · Cited by 24
Metadata
- Authors
- Castro, A., Scott, J. P., Grettie, D. P., Macfarlane, D., & Bailey, R. E.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1970-11-01
- Volume
- 19
- Issue
- 11
- Pages
- 842-851
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2111755638
- Cited by
- 71
- References
- 0
- FWCI
- 17.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasma Insulin and Glucose Responses of Healthy Subjects to Varying Glucose Loads During Three-hour Oral Glucose Tolerance Tests. https://app.cochat.ai/papers/10.2337/diab.19.11.842
- The paper
- Castro, A., Scott, J. P., Grettie, D. P., Macfarlane, D., & Bailey, R. E. (1970). Plasma Insulin and Glucose Responses of Healthy Subjects to Varying Glucose Loads During Three-hour Oral Glucose Tolerance Tests. Diabetes. https://doi.org/10.2337/diab.19.11.842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.