The DOI matches its Crossref record.
Characterization of Seven C-peptide Antisera
Abstract
The plasma C-peptide immunoreactivity (CPR) in 10 normal subjects varied considerably when measured with different antisera in parallel assays. The CPR level correlated with the blank “CPR” value measured in plasma devoid of C-peptide and to a lesser degree with the sensitivity of the standard curves obtained with the individual antisera. Storage of plasma samples at different temperatures and for different lengths of time before the analyses were carried out resulted In further variation in the CPR results. This was caused by a time- and temperature-dependent fall in CPR, which was more pronounced with some antisera than with others. This sensitivity to storage of plasma did not correlate with the antigenk characteristics of the antisera as determined by their reactivity with 11 specific fragments of the C-peptide molecule. The contribution of human proinsulin to the CPR concentration in normal subjects was considered to be negligible even though the relative immunoreactivity of human proinsulin and C-peptide ranged from 11 to 143 per cent among these antisera. These results suggest that differences in C-peptide antisera are a major reason for the variation in the concentration of circulating CPR as measured in different, C-peptide immunoassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Impact of sleep debt on metabolic and endocrine function
Spiegel, K., Leproult, R., & Van Cauter, E. (1999) · The Lancet · doi:10.1016/s0140-6736(99)01376-8 · Cited by 3,668
Anti-CD3 monoclonal antibody in new-onset type 1 diabetes mellitus
Herold, K. C., Hagopian, W., Auger, J. A., Poumian-Ruiz, E., Taylor, L., Donaldson, D., Gitelman, S. E., Harlan, D. M., Xu, D., Zivin, R. A., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012864 · Cited by 1,222
Vilsbøll, T., Krarup, T., Deacon, C. F., Madsbad, S., & Holst, J. J. (2001) · Diabetes · doi:10.2337/diabetes.50.3.609 · Cited by 884
Clinical Outcomes and Insulin Secretion After Islet Transplantation With the Edmonton Protocol
Ryan, E. A., Lakey, J. R. T., Rajotte, R. V., Korbutt, G. S., Kin, T., Imes, S., Rabinovitch, A., Elliott, J. F., Bigam, D., Kneteman, N. M., et al. (2001) · Diabetes · doi:10.2337/diabetes.50.4.710 · Cited by 864
Twenty-four-hour profiles and pulsatile patterns of insulin secretion in normal and obese subjects.
Polonsky, K. S., Given, B. D., & Van Cauter, E. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113339 · Cited by 763
Metadata
- Authors
- Faber, O. K., Binder, C., Markussen, J., Heding, L. G., Naithani, V. K., Kuzuya, H., Blix, P., Horwitz, D. L., & Rubenstein, A. H.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1978-02-01
- Volume
- 27
- Issue
- Supplement_1
- Pages
- 170-177
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W1991574615
- Cited by
- 229
- References
- 0
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Seven C-peptide Antisera. https://app.cochat.ai/papers/10.2337/diab.27.1.s170
- The paper
- Faber, O. K., Binder, C., Markussen, J., Heding, L. G., Naithani, V. K., Kuzuya, H., Blix, P., Horwitz, D. L., & Rubenstein, A. H. (1978). Characterization of Seven C-peptide Antisera. Diabetes. https://doi.org/10.2337/diab.27.1.s170
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.