Pulsatile, Synchronous Basal Insulin and Glucagon Secretion in Man
The DOI matches its Crossref record.
Abstract
The basal plasma insulin, glucagon, and glucose concentrations of 28 normal subjects were measured at 1-min intervals for periods of 45–120 min. Regular plasma insulin and/or glucagon cycles were detected in 11 subjects by autocorrelation (mean periods 13.1 and 13.7 min, respectively). Individual plasma insulin cycles were defined in all subjects (mean period 10.7 min, amplitude 1.1 mU/L), and were associated, after averaging, with plasma glucagon (amplitude 5.5 pg/ml) and plasma glucose (0.02 mmol/L) cycles. There was a significant correlation between the amplitudes of simultaneous plasma insulin and glucagon cycles (r = 0.23, P = < 0.05, N = 124). Cross-correlation demonstrated a delay of 2 min between the changes in plasma insulin and glucagon. No comparable oscillations in plasma pancreatic polypeptide were detected. The synchronous pulsatile secretion of glucagon and insulin may be a mechanism by which insulin's hepatic effects are limited, thereby maintaining hepatic glucose production but allowing sufficient peripheral insulin concentrations to inhibit excessive catabolism. The simultaneous pulses of insulin and glucagon may be stimulated by a pacemaker, with the A-B intercellular connections producing insulin and glucagon synchrony.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Impaired Pulsatile Secretion of Insulin in Relatives of Patients with Non-Insulin-Dependent Diabetes
O'Rahilly, S., Turner, R. C., & Matthews, D. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181902 · Cited by 540
Self-citationPulsatile Insulin Secretion: Detection, Regulation, and Role in Diabetes
Pørksen, N., Hollingdal, M., Juhl, C., Butler, P., Veldhuis, J. D., & Schmitz, O. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s245 · Cited by 223
“Half a century later, rapid oscillations in the peripheral insulin concentrations (2–6) and the islet hormones glucagon (3,5,7,8) and somatostatin (8–10) were demonstrated.”
BackgroundThe in vivo regulation of pulsatile insulin secretion
Pørksen, N. (2002) · Diabetologia · doi:10.1007/s125-002-8240-x · Cited by 174
SIMON, C., BRANDENBERGER, G., & FOLLENIUS, M. (1987) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-64-4-669 · Cited by 147
O'Meara, N. M., Sturis, J., Van Cauter, E., & Polonsky, K. S. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116560 · Cited by 132
Metadata
- Authors
- Lang, D. A., Matthews, D. R., Burnett, M., Ward, G. M., & Turner, R. C.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1982-01-01
- Volume
- 31
- Issue
- 1
- Pages
- 22-26
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W1987269897
- Cited by
- 124
- References
- 0
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulsatile, Synchronous Basal Insulin and Glucagon Secretion in Man. https://app.cochat.ai/papers/10.2337/diab.31.1.22
- The paper
- Lang, D. A., Matthews, D. R., Burnett, M., Ward, G. M., & Turner, R. C. (1982). Pulsatile, Synchronous Basal Insulin and Glucagon Secretion in Man. Diabetes. https://doi.org/10.2337/diab.31.1.22
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.