Influence of Plasma Glucose and Insulin Concentration on Plasma Glucose Clearance in Man
The DOI matches its Crossref record.
Abstract
We examined the influence of plasma glucose concentration on whole-body glucose uptake and glucose clearance at two physiologic levels of hyperinsulinemia. Twelve healthy, young volunteers were divided into two groups (A and B); each subject participated in three studies. In group A, plasma insulin was raised and maintained by ∼100 μU/ml for 3 h, while plasma glucose concentration was clamped at hypoglycemic (60 ± 1 mg/dl), euglycemic (89 ± 1 mg/dl), or hyperglycemic (165 ± 3 mg/dl) levels. In group B, plasma insulin was raised by ∼50 μU/ml, while plasma glucose was clamped at 62 ± 1,86 ±2, or 143 ± 3 mg/dl for 3 h. At the higher insulin level (group A), glucose uptake rose from 5.2 ± 0.5 to 7.3 ± 0.6 to 12.2 ±1.0 mg/min· kg as plasma glucose was varied from low to high levels; glucose clearance fell slightly from 8.8 ± 1.0 to 7.8 ± 0.7 to 7.3 ± 0.6 ml/min·kg during the hypo-, eu-, and hyperglycemic clamps (P = NS). At the lower insulin level (group B), glucose uptake rose from 6.0 ± 1.2 to 8.1 ±1.7 mg/min·kg (P < 0.05) with increasing glucose levels, whereas glucose clearance fell significantly (P < 0.01) from 9.7 ± 1.8 to 5.6 ±1.1 ml/min·kg. When the data from both groups were analyzed together, insulin had a stimulatory effect on both glucose uptake and clearance. Elevation of the plasma glucose level had a similar stimulatory effect on glucose uptake (P < 0.001) but inhibited glucose clearance (P < 0.01). This inhibition, however, was modest (14% for the change from hypo- to euglycemia, and 16% for the change from eu- to hyperglycemia). We conclude that physiologic hyperglycemia exerts a modest inhibitory effect on glucose clearance, which is largely overcome at higher, yet still physiologic, plasma insulin levels (∼100 μU/ml).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Model-Based Method for Assessing Insulin Sensitivity From the Oral Glucose Tolerance Test
Mari, A., Pacini, G., Murphy, E., Ludvik, B., & Nolan, J. J. (2001) · Diabetes Care · doi:10.2337/diacare.24.3.539 · Cited by 806
DeFronzo, R. A., Simonson, D., & Ferrannini, E. (1982) · Diabetologia · doi:10.1007/bf00253736 · Cited by 541
Self-citationDeFronzo, R. A., Ferrannini, E., & Simonson, D. C. (1989) · Metabolism · doi:10.1016/0026-0495(89)90129-7 · Cited by 515
Self-citationHow to measure insulin sensitivity
Ferrannini, E., & Mari, A. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00001 · Cited by 512
Self-citationDietary Carbohydrate (Amount and Type) in the Prevention and Management of Diabetes
Sheard, N. F., Clark, N. G., Brand-Miller, J. C., Franz, M. J., Pi-Sunyer, F. X., Mayer-Davis, E., Kulkarni, K., & Geil, P. (2004) · Diabetes Care · doi:10.2337/diacare.27.9.2266 · Cited by 475
“The rate of disappearance of glucose is largely influenced by insulin secretion and its action on target tissues (11).”
Background
Metadata
- Authors
- DeFronzo, R. A., & Ferrannini, E.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1982-08-01
- Volume
- 31
- Issue
- 8
- Pages
- 683-688
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2104802242
- Cited by
- 81
- References
- 0
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Plasma Glucose and Insulin Concentration on Plasma Glucose Clearance in Man. https://app.cochat.ai/papers/10.2337/diab.31.8.683
- The paper
- DeFronzo, R. A., & Ferrannini, E. (1982). Influence of Plasma Glucose and Insulin Concentration on Plasma Glucose Clearance in Man. Diabetes. https://doi.org/10.2337/diab.31.8.683
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.