Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 806

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

A Model-Based Method for Assessing Insulin Sensitivity From the Oral Glucose Tolerance Test

Open access
Mari, Andrea, Pacini, Giovanni, Murphy, Elaine, Ludvik, Bernhard, Nolan, John J.·2001·Diabetes Care

Abstract

OBJECTIVE—Available insulin sensitivity (IS) methods based on the oral glucose tolerance test (OGTT) are empirical. We used a glucose-insulin model to derive an OGTT-based IS (oral glucose insulin sensitivity [OGIS]) index, which predicts glucose clearance in a glucose clamp. We validated OGIS against clamp data. RESEARCH DESIGN AND METHODS—OGIS requires glucose and insulin concentrations from a 75-g OGTT at 0, 2, and 3 h (3-h OGTT) or at 0, 1.5, and 2 h (2-h OGTT). The formula includes six constants optimized to match the clamp results. For this purpose, 15 lean nondiabetic subjects (BMI < 25 kg/m2), 38 obese nondiabetic subjects (BMI > 25 kg/m2), and 38 subjects with type 2 diabetes randomly underwent an OGTT and a 120 mU · min−1 · m−2 insulin infusion euglycemic clamp. Glucose clearance (ClCLAMP), calculated as the ratio of glucose infusion to concentration during the last hour of the clamp, was compared with OGIS. OGIS was also tested on an independent group of 13 subjects with impaired glucose tolerance (IGT). RESULTS—OGIS and ClCLAMP were correlated in the whole group (R = 0.77, P < 0.0001), in the subgroups (lean: R = 0.59; obese: R = 0.73; type 2 diabetes: R = 0.49; P < 0.02), and in the independent IGT group (R = 0.65, P < 0.02). Reproducibility of OGIS and ClCLAMP were similar (coefficients of variation: OGIS 7.1%, ClCLAMP 6.4%). OGIS was as effective as ClCLAMP in discriminating between groups (for OGIS, lean vs. obese: 440 ± 16 vs. 362 ± 11 ml · min−1 · m−2, P < 0.001; lean vs. type 2 diabetes: 440 ± 16 vs. 239 ± 7, P < 0.0001; obese vs. type 2 diabetes: 362 ± 11 vs. 239 ± 7, P < 0.0001; results were similar for ClCLAMP). The relationships between IS and BMI, fasting plasma insulin, and insulin secretion (calculated from the OGTT insulin concentration) were examined. OGIS yielded results similar to ClCLAMP and fully consistent with established physiological principles. The performance of the index for the 3-h and 2-h OGTT was similar. CONCLUSIONS—OGIS is an index of IS in good agreement with the clamp. Because of its simplicity (only three blood samples required), this method has potential use for clinical investigation including large-scale epidemiological studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.24.3.539

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 806

Metadata

Authors
Mari, A., Pacini, G., Murphy, E., Ludvik, B., & Nolan, J. J.
Venue
Diabetes Care
Published
2001-03-01
Volume
24
Issue
3
Pages
539-548
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2127277443
Cited by
806
References
7
FWCI
9.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Model-Based Method for Assessing Insulin Sensitivity From the Oral Glucose Tolerance Test. https://app.cochat.ai/papers/10.2337/diacare.24.3.539
The paper
Mari, A., Pacini, G., Murphy, E., Ludvik, B., & Nolan, J. J. (2001). A Model-Based Method for Assessing Insulin Sensitivity From the Oral Glucose Tolerance Test. Diabetes Care. https://doi.org/10.2337/diacare.24.3.539

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.