Efficacy of Pulsatile Versus Continuous Insulin Administration on Hepatic Glucose Production and Glucose Utilization in Type I Diabetic Humans
The DOI matches its Crossref record.
Abstract
To evaluate the role of pulsatile insulin administration, hepatic glucose production (HGP) and utilization were studied in type I diabetic patients in the fasting state and during a euglycemic insulin (1 mU · kg−1 · min−1 i.v.) clamp with continuous and pulsatile insulin administration. In the latter study, insulin was infused at twice the continuous rate with 3-min-on/7-min-off intervals, thereby reducing total insulin delivery by 40%. The restraining effect of pulsatile insulin on basal HGP (1.91 ± 0.35 mg · kg−1 · min−1) was equipotent to continuous insulin exposure (1.80 ± 0.17 mg · kg−1 min−1). During the insulin-clamp studies, HGP was equally suppressed by pulsed (0.62 ± 0.12 mg · kg−1 min−1) as by continuous insulin infusion (0.63 ± 0.12 mg · kg−1 · min−1). Insulin-stimulated glucose utilization was not significantly altered in either study (2.55 ± 0.27 vs. 2.92 ± 0.23 mg · kg−1 min−1). When in further studies the total insulin dose given during the pulsatile study was infused continuously (0.6 mU · kg−1 · min−1), HGP in the basal state and residual HGP during the insulin-clamp study were 25–30% higher than in the pulsatile experiments, whereas glucose utilization was not significantly different. In conclusion, by reducing total hormone delivery by up to 40%, but given in a pulsatile fashion, insulin is equally potent in controlling HGP as continuous insulin administration. This greater efficacy of pulsatile exposure in suppressing HGP is accompanied by an equipotent effect on glucose utilization. Application of pulsatile insulin substitution in intravenous-pump users may reduce systemic hyperinsulinemia and, in the long run, insulin resistance by reversing downregulation of insulin receptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Autonomic regulation of islet hormone secretion - Implications for health and disease
Ahrén, B. (2000) · Diabetologia · doi:10.1007/s001250051322 · Cited by 909
Insulin Resistance and Hyperinsulinemia
Shanik, M. H., Xu, Y., Škrha, J., Dankner, R., Zick, Y., & Roth, J. (2008) · Diabetes Care · doi:10.2337/dc08-s264 · Cited by 791
Age-related changes in glucose metabolism, hyperglycemia, and cardiovascular risk
Chia, C. W., Egan, J. M., & Ferrucci, L. (2018) · Circulation Research · doi:10.1161/circresaha.118.312806 · Cited by 454
Juhl, C. B., Hollingdal, M., Sturis, J., Jakobsen, G., Agersø, H., Veldhuis, J., Pørksen, N., & Schmitz, O. (2002) · Diabetes · doi:10.2337/diabetes.51.2.424 · Cited by 264
Chronobiology in the endocrine system
Haus, E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.01.001 · Cited by 225
“In contrast, the apparent improvement of glucose utilization related to the high-frequency pulses (of 10–15 min periods) seems to be due to an inhibition of hepatic glucose production [339,375].”
Background
Metadata
- Authors
- Bratusch-Marrain, P. R., Komjati, M., & Waldhäusl, W. K.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1986-08-01
- Volume
- 35
- Issue
- 8
- Pages
- 922-926
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2105538438
- Cited by
- 149
- References
- 0
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy of Pulsatile Versus Continuous Insulin Administration on Hepatic Glucose Production and Glucose Utilization in Type I Diabetic Humans. https://app.cochat.ai/papers/10.2337/diab.35.8.922
- The paper
- Bratusch-Marrain, P. R., Komjati, M., & Waldhäusl, W. K. (1986). Efficacy of Pulsatile Versus Continuous Insulin Administration on Hepatic Glucose Production and Glucose Utilization in Type I Diabetic Humans. Diabetes. https://doi.org/10.2337/diab.35.8.922
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.