Microvascular Blood Flow, Volume, and Velocity Measured by Laser Doppler Techniques in IDDM
The DOI matches its Crossref record.
Abstract
A laser Doppler device with the capability to simultaneously measure skin blood flow, microvascular volume, and erythrocyte velocity was used to assess blood flow changes in 35 insulin-dependent diabetes mellitus (IDDM) subjects, mean age 33 ± 1 yr, with average duration of diabetes 14 ± 1 yr, and in a nondiabetic control group. Blood flow was determined at 35 and 44°C at several sites on the upper and the lower extremities with a temperature-regulated probe. Blood flow was highest at both temperatures on the pulps of the index finger and the first toe, regions of high density of arteriovenous anastomoses. There was significantly greater blood flow at most locations for the nondiabetic than the diabetic group at 35°C, and the differences between the two groups were substantially larger at 44°C. At 44°C, blood flow in the control group was ∼40% greater in the upper extremity and 50% greater in the lower extremity than it was in the diabetic subjects. The differences were attributed to decreases of both microvascular volume and velocity in the diabetic group. In the upper extremity, volumes in the diabetic patients were 10–15% lower and velocities 10–40% lower than in the nondiabetic subjects. In the lower extremity, volumes were 20–25% lower and velocities 40–50% lower. We conclude that laser Doppler techniques can be used to assess microvascular changes in the skin of diabetic patients. This approach may be useful to evaluate and model diabetic microangiopathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Microvascular dysfunction in diabetic foot disease and ulceration
Chao, C. Y. L., & Cheing, G. L. Y. (2009) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.1004 · Cited by 211
“[90] found that the arteriovenous shunt flow was reduced in patients with type 1 diabetes as compared with healthy control subjects, which is contradictory to what happens in capillary steal syndrome.”
ResultJungheim, K., & Koschinsky, T. (2002) · Diabetes Care · doi:10.2337/diacare.25.6.956 · Cited by 114
Forst, T., Caduff, A., Talary, M., Weder, M., Brändle, M., Kann, P., Flacke, F., Friedrich, C., & Pfützner, A. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.94 · Cited by 51
Early stage detection of conduit artery endothelial dysfunction in patients with type 1 diabetes
Bellien, J., Costentin, A., Dutheil-Maillochaud, B., Iacob, M., Kuhn, J.-M., Thuillez, C., & Joannides, R. (2010) · Diabetes and Vascular Disease Research · doi:10.1177/1479164109360470 · Cited by 32
Metadata
- Authors
- Rendell, M., Bergman, T., O'Donnell, G., Drobny, E., Borgos, J., & Bonner, R. F.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1989-07-01
- Volume
- 38
- Issue
- 7
- Pages
- 819-824
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2131277286
- Cited by
- 125
- References
- 0
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microvascular Blood Flow, Volume, and Velocity Measured by Laser Doppler Techniques in IDDM. https://app.cochat.ai/papers/10.2337/diab.38.7.819
- The paper
- Rendell, M., Bergman, T., O'Donnell, G., Drobny, E., Borgos, J., & Bonner, R. F. (1989). Microvascular Blood Flow, Volume, and Velocity Measured by Laser Doppler Techniques in IDDM. Diabetes. https://doi.org/10.2337/diab.38.7.819
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.