Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Novel Glucosensor for Hypoglycemic Detection Localized to the Portal Vein

Open access
Hevener, Andrea L, Bergman, Richard N, Donovan, Casey M·1997·Diabetes

Abstract

In this investigation, we sought to constrain the locus of essential portohepatic glucosensors and test the hypothesis that they reside strictly in the portal vein and not the liver. Male Wistar rats were chronically cannulated in the carotid artery (sampling), jugular vein (infusion), and portal vein, either adjacent to (PORADJ, 0.6 ± 0.1 cm, n = 6) or upstream from (PORUPS, 2.7 ± 0.1 cm, n = 8) the liver. Animals were exposed to one of three protocols distinguished by the site of glucose infusion: PORUPS, PORADJ, or peripheral (PER). Systemic hypoglycemia (2.4 ± 0.1 mmol/1) was induced via jugular vein insulin infusion (50 mU · kg−1 · min−1). Arterial plasma catecholamines were assessed at basal (−30 and 0 min) and during sustained hypoglycemia (60, 75, 90, 105 min). By design, hepatic glucose was significantly elevated during PORUPS and PORADJ versus PER (4.3 ± 0.1 vs. 2.4 ± 0.1 mmol/l, respectively; P < 0.05). There were no significant differences between protocols in arterial glucose or insulin concentrations (9,372 ± 1,798 pmol/l). When liver and systemic glucose concentrations were allowed to fall concomitantly (PER), epinephrine was elevated 16-fold above basal levels (3.0 ± 0.6 vs. 46.4 ± 4.3 nmol/l, P < 0.001). When portohepatic normoglycemia was maintained during PORUPS, a 67% suppression in the epinephrine response versus that during PER was observed (P < 0.001). However, when the cannula was advanced adjacent to the liver, by comparison with PER, there was no suppression in the sympathoadrenal response (P = 0.73). While both PORUPS and PORADJ yielded elevated liver glycemia in the face of systemic hypoglycemia, only POR(UPS yielded an elevated portal vein glucose concentration. That only PORUPS resulted in a significant suppression of the sympathoadrenal response is consistent with the localization of the glucosensors to the portal vein.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diab.46.9.1521

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 176

Metadata

Authors
Hevener, A. L., Bergman, R. N., & Donovan, C. M.
Venue
Diabetes
Published
1997-09-01
Volume
46
Issue
9
Pages
1521-1525
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2049228990
Cited by
176
References
1
FWCI
3.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Novel Glucosensor for Hypoglycemic Detection Localized to the Portal Vein. https://app.cochat.ai/papers/10.2337/diab.46.9.1521
The paper
Hevener, A. L., Bergman, R. N., & Donovan, C. M. (1997). Novel Glucosensor for Hypoglycemic Detection Localized to the Portal Vein. Diabetes. https://doi.org/10.2337/diab.46.9.1521

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.