Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record.

Vibratory and Cooling Detection Thresholds Compared With Other Tests in Diagnosing and Staging Diabetic Neuropathy

Dyck, Peter James, Bushek, Wilfred, Spring, Eileen M, Karnes, Jeannine L, Litchy, William J, O'Brien, Peter C, Service, F John·1987·Diabetes Care

Abstract

Increasingly more tests are being used to detect and characterize diabetic polyneuropathy, but their value in setting minimal criteria for the diagnosis of neuropathy and for staging severity remains inadequately studied. In 180 diabetics, we compared the percentage of patients with test abnormalities and associations among test results, evaluating neuropathic symptoms [neuropathy symptom score (NSS) and neuropathy scale of neuropathy symptom profile (NNSP)], deficits [neurologic disability score (NDS) and vibratory (VDT) and cooling (CDT) detection thresholds], or nerve dysfunction [nerve conduction (NC)]. The percentage of patients that were abnormal varied considerably depending on criteria for abnormality and the tests used. Abnormality (≥ 3 SD of 1 or more parameters) of NC of one or more of four nerves occurred in 80%, of two or more in 69%, of three or more in 46%, and of four in 21%. Similarly, for other tests, the rate of abnormality decreased with use of increasingly stringent criteria. Setting the criteria for abnormal NC at abnormality of two or more nerves, NSS at ≥ 1, NDS at > 6, NNSP at ≥ 97.5th percentile, and at ≥ 95th percentile for the other tests, NC was abnormal in 69%, NSS in 54%, NDS in 48%, NNSP in 47%, VDT in 44%, and CDT in 35%. Abnormality of any two or more of the six tests evaluated occurred in 64% of patients. We estimated that at least 16% of patients without abnormal NC (<2 abnormal nerves) had other findings indicative of neuropathy. By regression analysis, results of one test were in almost all cases associated with those of another test, but the association was not close enough to be predictive. Therefore, although NC provides objective and repeatable results, symptoms and deficits must be measured independently. Assuming no differences between groups of patients, the standardized and validated test (NNSP, VDT, or CDT) should provide the same results at different medical centers. By contrast, the results of NSS or NDS tests, with less standardized approaches and based on the judgment of physicians, might not provide the same results at different medical centers. Tests such as the ones described here may be used to define minimal criteria for the diagnosis of polyneuropathy and for staging its severity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.10.4.432

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Dyck, P. J., Bushek, W., Spring, E. M., Karnes, J. L., Litchy, W. J., O'Brien, P. C., & Service, F. J.
Venue
Diabetes Care
Published
1987-07-01
Volume
10
Issue
4
Pages
432-440
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2092780614
Cited by
179
References
0
FWCI
5.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vibratory and Cooling Detection Thresholds Compared With Other Tests in Diagnosing and Staging Diabetic Neuropathy. https://app.cochat.ai/papers/10.2337/diacare.10.4.432
The paper
Dyck, P. J., Bushek, W., Spring, E. M., Karnes, J. L., Litchy, W. J., O'Brien, P. C., & Service, F. J. (1987). Vibratory and Cooling Detection Thresholds Compared With Other Tests in Diagnosing and Staging Diabetic Neuropathy. Diabetes Care. https://doi.org/10.2337/diacare.10.4.432

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.