CoChat

Continuous Subcutaneous Insulin Infusion

Open access
· 1992 · Diabetes Care
Cited by 111

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI) represent two strategies of intensive insulin therapy, obtaining a strict metabolic control. The importance of such rigorous metabolic control in reducing the frequency and severity of diabetes long-term complications was highlighted by the Diabetes Control and Complication Trial (DCCT). AIM: To review the experience in the use of ISCI at Hospital São João, comparing it with the therapeutic modality of MID, regarding metabolic control, weight and body mass index (BMI), microalbuminuria, frequency of adverse events, lipid profile and quality of life. METHODS: This retrospective, observational study included 25 type 1 diabetic patients followed-up on Endocrinology outpatient at Hospital São João, receiving CSII for more than 3 months after they were treated with MDI also for a period exceeding 3 months. For both periods of treatment, clinical data were obtained on the quality of glycaemic control (assessed by the levels of glycated hemoglobin--A1c), lipid profile, weight and body mass index (BMI) and microalbuminuria. To evaluate the impact on quality of life we used the ADDQoL questionnaire. A questionnaire was also used to determine the frequency of adverse events (severe hypoglycemia and ketoacidosis). RESULTS: The sample of 25 subjects with mean age of 33.35 ± 9.59 years, with a duration of disease, on average, of 17.1 ± 8.15 years and receiving ISCI for an average of 2.48 ± 1 08 years, obtained a decrease of 1.1% (p = 0.001) on the median value of A1c between 3 and 6 months of treatment when compared to MDI, reduction sustained throughout the analyzed period. The variation of the daily insulin requirements after pump placement was 12.75 units of insulin (p = 0.015), equivalent to a decrease of 0.20 units/kg (p = 0.023). The median of the distribution of BMI decreased 0.48 kg/m2 (p = 0.507) during CSII. The parameters of lipid profile and microalbuminuria showed no trend upward or downward after institution of CSII. The score obtained in the ADDQoL questionnaire was greater with CSII, the difference between the medians of the score distribution, before and after pump placement, was 0.056 (p = 0.92). There was a subjective perception of reduced frequency of adverse events with ISCI. CONCLUSION: The introduction of CSII allowed optimization of metabolic control, reduction of the daily insulin requirements and achievement of a higher level of satisfaction with no change in lipid profile, no weight gain and without increasing the frequency of adverse events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.15.2.34

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 111

Metadata

Venue
Diabetes Care
Published
1992-04-01
Volume
15
Issue
Supplement_2
Pages
34-35
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W1482105209
Cited by
111
References
2
FWCI
0.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Subcutaneous Insulin Infusion. https://app.cochat.ai/papers/10.2337/diacare.15.2.34
The paper
Continuous Subcutaneous Insulin Infusion. (1992). Diabetes Care. https://doi.org/10.2337/diacare.15.2.34

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.