Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

Screening for Diabetic Retinopathy: The wide-angle retinal camera

Pugh, Jacqueline A, Jacobson, James M, Van Heuven, W A J, Watters, John A, Tuley, Michael R, Lairson, David R, Lorimor, Ronald J, Kapadia, Asha S, Velez, Ramon·1993·Diabetes Care

Abstract

OBJECTIVE— To define the test characteristics of four methods of screening for diabetic retinopathy. RESEARCH DESIGN AND METHODS— Four screening methods (an exam by an ophthalmologist through dilated pupils using direct and indirect ophthalmoscopy, an exam by a physician's assistant through dilated pupils using direct ophthalmoscopy, a single 45° retinal photograph without pharmacological dilation, and a set of three dilated 45° retinal photographs) were compared with a reference standard of stereoscopic 30° retinal photographs of seven standard fields read by a central reading center. Sensitivity, specificity, and positive and negative likelihood ratios were calculated after dichotomizing the retinopathy levels into none and mild nonproliferative versus moderate to severe nonproliferative and proliferative. Two sites were used. All patients with diabetes in a VA hospital outpatient clinic between June 1988 and May 1989 were asked to participate. Patients with diabetes identified from a laboratory list of elevated serum glucose values were recruited from a DOD medical center. RESULTS— The subjects (352) had complete exams excluding the exam by the physician's assistant that was added later. The sensitivities, specificities, and positive and negative likelihood ratios are as follows: ophthalmologist 0.33, 0.99, 72, 0.67; photographs without pharmacological dilation 0.61, 0.85, 4.1, 0.46; dilated photographs 0.81, 0.97, 24, 0.19; and physician's assistant 0.14, 0.99, 12, 0.87. CONCLUSIONS— Fundus photographs taken by the 45° camera through pharmacologically dilated pupils and read by trained readers perform as well as ophthalmologists for detecting diabetic retinopathy. Physician extenders can effectively perform the photography with minimal training but would require more training to perform adequate eye exams. In this older population, many patients did not obtain adequate nonpharmacological dilation for use of the 45° camera.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.16.6.889

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Pugh, J. A., Jacobson, J. M., Van Heuven, W. A. J., Watters, J. A., Tuley, M. R., Lairson, D. R., Lorimor, R. J., Kapadia, A. S., & Velez, R.
Venue
Diabetes Care
Published
1993-06-01
Volume
16
Issue
6
Pages
889-895
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2030085186
Cited by
172
References
0
FWCI
1.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening for Diabetic Retinopathy: The wide-angle retinal camera. https://app.cochat.ai/papers/10.2337/diacare.16.6.889
The paper
Pugh, J. A., Jacobson, J. M., Van Heuven, W. A. J., Watters, J. A., Tuley, M. R., Lairson, D. R., Lorimor, R. J., Kapadia, A. S., & Velez, R. (1993). Screening for Diabetic Retinopathy: The wide-angle retinal camera. Diabetes Care. https://doi.org/10.2337/diacare.16.6.889

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.