The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Symmetrization of the Blood Glucose Measurement Scale and Its Applications
Abstract
OBJECTIVE: To introduce a data transformation that enhances the power of blood glucose data analyses. RESEARCH DESIGN AND METHODS: In the standard blood glucose scale, hypoglycemia (blood glucose, <3.9 mmol/l) and hyperglycemia (blood glucose, >10 mmol/l) have very different ranges, and euglycemia is not central in the entire blood glucose range (1.1–33.3 mmol/l). Consequently, the scale is not symmetric and its clinical center (blood glucose, 6–7 mmol/l) is distant from its numerical center (blood glucose, 17 mmol/l). As a result, when blood glucose readings are analyzed, the assumptions of many parametric statistics are routinely violated. We propose a logarithmic data transformation that matches the clinical and numerical center of the blood glucose scale, thus making the transformed data symmetric. RESULTS: The transformation normalized 203 out of 205 data samples containing 13,584 blood glucose readings of 127 type 1 diabetic individuals. An example illustrates that the mean and standard deviation based on transformed, rather than on raw, data better described subject's blood glucose distribution. Based on transformed data: 1) the low blood glucose index predicted the occurrence of severe hypoglycemia, while the raw blood glucose data (and glycosylated hemoglobin levels) did not; 2) the high blood glucose index correlated with the subjects' glycosylated hemoglobin (r = 0.63, P <0.001); and 3) the low plus high blood glucose index was more sensitive than the raw data to a treatment (blood glucose awareness training) designed to reduce the range of blood glucose fluctuations. CONCLUSIONS: Using symmetrized, instead of raw, blood glucose data strengthens the existing data analysis procedures and allows for the development of new statistical techniques. It is proposed that raw blood glucose data should be routinely transformed to a symmetric distribution before using parametric statistics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of transformations (with discussion)
Box, G. E. P. (1964) · Journal of the Royal Statistical Society Series A (Statistics in Society) · Cited by 1,891
A multicenter evaluation of blood glucose awareness training-II
Cox, D., Gonder-Frederick, L., Polonsky, W., Schlundt, D., Julian, D., & Clarke, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.523 · Cited by 132
Self-citation
Cited by
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“A key element to the interpretation of SMBG signals is the use of the BG Risk Space, which was introduced over ten years ago and was based on a transformation of the BG scale that corrects an inherent asymmetry of the hypoglycemic versus hyperglycemic ranges [184].”
Self-citationGlucose variability is associated with intensive care unit mortality*
Hermanides, J., Vriesendorp, T. M., Bosman, R. J., Zandstra, D. F., Hoekstra, J. B., & DeVries, J. H. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181cc4be9 · Cited by 437
Glucose Variability; Does It Matter?
Siegelaar, S. E., Holleman, F., Hoekstra, J. B. L., & DeVries, J. H. (2010) · Endocrine Reviews · doi:10.1210/er.2009-0021 · Cited by 409
Evaluation of a New Measure of Blood Glucose Variability in Diabetes
Kovatchev, B. P., Otto, E., Cox, D., Gonder-Frederick, L., & Clarke, W. (2006) · Diabetes Care · doi:10.2337/dc06-1085 · Cited by 333
Self-citationEffectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Metadata
- Authors
- Kovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., & Clarke, W.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1997-11-01
- Volume
- 20
- Issue
- 11
- Pages
- 1655-1658
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2087220735
- Cited by
- 257
- References
- 2
- FWCI
- 0.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Symmetrization of the Blood Glucose Measurement Scale and Its Applications. https://app.cochat.ai/papers/10.2337/diacare.20.11.1655
- The paper
- Kovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., & Clarke, W. (1997). Symmetrization of the Blood Glucose Measurement Scale and Its Applications. Diabetes Care. https://doi.org/10.2337/diacare.20.11.1655
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.