The DOI matches its Crossref record.
Insulin aspart (B28 asp-insulin): a fast-acting analog of human insulin: absorption kinetics and action profile compared with regular human insulin in healthy nondiabetic subjects
Abstract
OBJECTIVE: To study the pharmacokinetic and pharmacodynamic profile of insulin aspart (a new fast-acting human insulin analog) after subcutaneous administration in the deltoid, abdominal, and thigh sites and to compare this profile with regular human insulin (Novolin; Novo Nordisk A/S, Copenhagen). RESEARCH DESIGN AND METHODS: A total of 20 healthy subjects were studied in a single-center six-period double-blind randomized crossover trial with 6 study days and a washout period of 1 week between each single daily dose of the trial drug. Subjects were randomized to receive a single dose of 0.2 U/kg of insulin aspart or regular insulin on each of the 6 study days in three different sites (the deltoid, the abdomen, and the thigh) during a 10-h euglycemic clamp (two drugs and three injection sites). Pharmacokinetic and pharmacodynamic measurements were derived from blood sample measurements of glucose, insulin, and C-peptide during these clamps. RESULTS: The pharmacodynamic data from the euglycemic clamp study showed that, regardless of injection site, the maximal glucose infusion rate (GIR Cmax) was greater and occurred at an earlier time (GIR Tmax) after administration of insulin aspart than regular insulin (GIR Cmax: abdomen 813 vs. 708, deltoid 861 vs. 736, and thigh 857 vs. 720 g/min, P < 0.05 for all; GIR Tmax: abdomen 94 vs. 173, deltoid 111 vs. 192, and thigh 145 vs. 193 g/min, P < 0.05 for all). Pharmacokinetic parameters were also consistent with faster absorption and higher peak insulin concentrations after insulin aspart administration. From all sites, the peak insulin concentration (Cmax) was higher and occurred earlier (Tmax) after administration of insulin aspart than of regular insulin (Cmax: abdomen 501 vs. 260, deltoid 506 vs. 252, thigh 422 vs. 220 pmol/l, P < 0.001 for all sites; Tmax: abdomen 52 vs. 109, deltoid 54 vs. 98, and thigh 60 vs. 107 min, P < 0.01 for all sites). The absorption and glucose-lowering action of insulin aspart did not differ between sites (similar GIR Cmax, Tmax, and area under the curve parameters). However, the duration of the glucose-lowering effect was up to 34 min shorter (P < 0.01) for the abdomen injections than for the deltoid or thigh injections (lower time of 50% glucose disposal). In addition, the amount of glucose infused was significantly lower by 10-14% in the abdomen than in other sites. CONCLUSIONS: Subcutaneous administration of insulin aspart causes a more rapid and intense maximal effect compared with regular insulin during euglycemic clamp studies in nondiabetic subjects. Abdominal administration of insulin aspart has a shorter duration of glucose-lowering effect compared with administration in the deltoid or thigh.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Insulin prescriptions—particularly glargine (long-acting) and aspart (rapid-acting)—were the next strongest clinical predictors, suggesting that patients requiring both basal and rapid-acting insulin have more complex or less stable disease [81,82].”
From Machine learning-driven risk prediction for post-hospitalization diabetes case management: Integrating clinical and social determinants of health (2026) · cites this paper as [82]
Citations
Cites
Still being checked.
Cited by
Sorted by citations
Hirsch, I. B. (2005) · New England Journal of Medicine · doi:10.1056/nejmra040832 · Cited by 667
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286
Raskin, P., Bode, B. W., Marks, J. B., Hirsch, I. B., Weinstein, R. L., McGill, J. B., Peterson, G. E., Mudaliar, S. R., & Reinhardt, R. R. (2003) · Diabetes Care · doi:10.2337/diacare.26.9.2598 · Cited by 248
Self-citationRaskin, P., Guthrie, R. A., Leiter, L. A., Riis, A. H., & Jovanovič, L. (2000) · Diabetes Care · doi:10.2337/diacare.23.5.583 · Cited by 230
Danne, T., Phillip, M., Buckingham, B. A., Jarosz-Chobot, P. A., Saboo, B., Urakami, T., Battelino, T., Hanås, R., & Ethel Codner, D. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12718 · Cited by 226
Metadata
- Authors
- Mudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R.
- Affiliations
- University of California San Diego (US)
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1999-09-01
- Volume
- 22
- Issue
- 9
- Pages
- 1501-1506
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2150939399
- Cited by
- 276
- References
- 0
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 4 · 2023: 8 · 2022: 6 · 2021: 14 · 2020: 3 · 2019: 4 · 2018: 8 · 2017: 11 · 2016: 10 · 2015: 12 · 2014: 13 · 2013: 10 · 2012: 20
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Center for Research Resources (MO1 RR00827, M01RR000827)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Keywords
- insulin aspart, regular insulin, insulin pharmacokinetics, insulin pharmacodynamics, subcutaneous injection site, deltoid muscle, thigh, glucose infusion rate, euglycemic clamp, C-peptide, insulin sensitivity, insulin clearance
- MeSH terms
- Absorption, Adult, Double-Blind Method, Humans, Hypoglycemic Agents, Injections, Intramuscular, Injections, Subcutaneous, Insulin, Male, Reference Values, Glucose Clamp Technique, Cross-Over Studies, Insulin Aspart
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review