Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,042

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity.

Stumvoll, M, Mitrakou, A, Pimenta, W, Jenssen, T, Yki-Järvinen, H, Van Haeften, T, Renn, W, Gerich, J·2000·Diabetes Care

Abstract

OBJECTIVE: The oral glucose tolerance test (OGTT) has often been used to evaluate apparent insulin release and insulin resistance in various clinical settings. However, because insulin sensitivity and insulin release are interdependent, to what extent they can be predicted from an OGTT is unclear. RESEARCH DESIGN AND METHODS: We studied insulin sensitivity using the euglycemic-hyperinsulinemic clamp and insulin release using the hyperglycemic clamp in 104 nondiabetic volunteers who had also undergone an OGTT. Demographic parameters (BMI, waist-to-hip ratio, age) and plasma glucose and insulin values from the OGTT were subjected to multiple linear regression to predict the metabolic clearance rate (MCR) of glucose, the insulin sensitivity index (ISI), and first-phase (1st PH) and second-phase (2nd PH) insulin release as measured with the respective clamps. RESULTS: The equations predicting MCR and ISI contained BMI, insulin (120 min), and glucose (90 min) and were highly correlated with the measured MCR (r = 0.80, P < 0.00005) and ISI (r = 0.79, P < 0.00005). The equations predicting 1st PH and 2nd PH contained insulin (0 and 30 min) and glucose (30 min) and were also highly correlated with the measured 1st PH (r = 0.78, P < 0.00005) and 2nd PH (r = 0.79, P < 0.00005). The parameters predicted by our equations correlated better with the measured parameters than homeostasis model assessment for secretion and resistance, the delta30-min insulin/delta30-min glucose ratio for secretion and insulin (120 min) for insulin resistance taken from the OGTT. CONCLUSIONS: We thus conclude that predicting insulin sensitivity and insulin release with reasonable accuracy from simple demographic parameters and values obtained during an OGTT is possible. The derived equations should be used in various clinical settings in which the use of clamps or the minimal model would be impractical.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.23.3.295

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 1,042

Metadata

Authors
Stumvoll, M., Mitrakou, A., Pimenta, W., Jenssen, T., Yki-Järvinen, H., Van Haeften, T., Renn, W., & Gerich, J.
Venue
Diabetes Care
Published
2000-03-01
Volume
23
Issue
3
Pages
295-301
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2132806782
Cited by
1,042
References
1
FWCI
25.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity. https://app.cochat.ai/papers/10.2337/diacare.23.3.295
The paper
Stumvoll, M., Mitrakou, A., Pimenta, W., Jenssen, T., Yki-Järvinen, H., Van Haeften, T., Renn, W., & Gerich, J. (2000). Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity. Diabetes Care. https://doi.org/10.2337/diacare.23.3.295

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.