The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Pharmacokinetics of 125I-labeled insulin glargine (HOE 901) in healthy men: comparison with NPH insulin and the influence of different subcutaneous injection sites.
Open accessAbstract
OBJECTIVE: To determine the subcutaneous absorption rates and the appearance in plasma of 3 formulations of the long-acting human insulin analog insulin glargine (HOE 901) differing only in zinc content (15, 30, and 80 microg/ml). RESEARCH DESIGN AND METHODS: We conducted 2 studies. Study 1 compared the subcutaneous abdominal injection of 0.15 U/kg of 125I-labeled insulin glargine[15], insulin glargine[80], NPH insulin, and placebo. In study 2, 0.2 U/kg of insulin glargine[30] was injected into the arm, leg, and abdominal regions. Both studies had a randomized crossover design; each enrolled 12 healthy men, aged 18-50 years. RESULTS: In study 1, the time in hours for 25% of the administered radioactivity to disappear after bolus subcutaneous injection (T75%) for NPH insulin indicated a significantly faster absorption rate compared with the 2 insulin glargine formulations (3.2 vs. 8.8 and 11.0 h, respectively P < 0.0001). Mean residual radioactivity with NPH insulin was also significantly lower at 24 h (21.9 vs. 43.8 and 52.2%, P < 0.0001). The calculated plasma exogenous insulin concentrations after NPH insulin were substantially higher than those with insulin glargine, reaching a peak within the first 6 h after administration before declining. Insulin glargine, however, did not exhibit a distinct peak. Weighted average plasma glucose concentration between 0 and 6 h was significantly lower after NPH compared with insulin glargine (P < 0.001). In study 2, there were no significant differences in the absorption characteristics of insulin glargine between the 3 injection sites (T75% = 11.9, 15.3, and 13.2 h for arm, leg, and abdomen, respectively) or in residual radioactivity at 24 h. CONCLUSIONS: Subcutaneous absorption of insulin glargine is delayed compared with NPH insulin. There is little or no difference in the absorption rate of insulin glargine between the main subcutaneous injection sites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binder, C., Lauritzen, T., Faber, O., & Pramming, S. (1984) · Diabetes Care · doi:10.2337/diacare.7.2.188 · Cited by 341
Cited by
Hirsch, I. B. (2005) · New England Journal of Medicine · doi:10.1056/nejmra040832 · Cited by 667
The Mechanism of Protraction of Insulin Detemir, a Long-Acting, Acylated Analog of Human Insulin
Havelund, S., Plum, A., Ribel, U., Jonassen, I., Vølund, A., Markussen, J., & Kurtzhals, P. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000036926.54824.37 · Cited by 429
Owens, D. R., Zinman, B., & Bolli, G. B. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05842-1 · Cited by 373
Self-citationReduced Hypoglycemia Risk With Insulin Glargine
Rosenstock, J., Dailey, G., Massi-Benedetti, M., Fritsche, A., Lin, Z., & Salzman, A. (2005) · Diabetes Care · doi:10.2337/diacare.28.4.950 · Cited by 371
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286
Metadata
- Authors
- Owens, D. R., Coates, P. A., Luzio, S. D., Tinbergen, J. P., & Kurzhals, R.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2000-06-01
- Volume
- 23
- Issue
- 6
- Pages
- 813-819
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2032666450
- Cited by
- 200
- References
- 1
- FWCI
- 7.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pharmacokinetics of 125I-labeled insulin glargine (HOE 901) in healthy men: comparison with NPH insulin and the influence of different subcutaneous injection sites. https://app.cochat.ai/papers/10.2337/diacare.23.6.813
- The paper
- Owens, D. R., Coates, P. A., Luzio, S. D., Tinbergen, J. P., & Kurzhals, R. (2000). Pharmacokinetics of 125I-labeled insulin glargine (HOE 901) in healthy men: comparison with NPH insulin and the influence of different subcutaneous injection sites. Diabetes Care. https://doi.org/10.2337/diacare.23.6.813
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.