Risky Delay of Hypoglycemia Detection by Glucose Monitoring at the Arm
The DOI matches its Crossref record.
Abstract
Several devices for self-monitoring of blood glucose (SMBG) (e.g., AtLast, Amira; OneTouch Ultra, LifeScan; FreeStyle, TheraSense, Alameda, CA; Glucometer-Elite XL+Microlet-Vaculance, Bayer; and Sof-Tact, Abbott) recently received Food and Drug Administration approval for alternative site monitoring of capillary blood glucose. These alternatives are marketed with considerable efforts under the assumption that capillary blood glucose measurements, e.g., those taken at the forearm, do not differ from the results obtained by classic finger pricking. Diabetic patients using different devices for SMBG reported discrepancies between clinical symptoms of hypoglycemia and normoglycemic SMBG values at the forearm. Neither standardized quality control assessments of technical performance of such SMBG devices (1,2) nor patient device handling resulted in any obvious explanation of the reported discrepancies. Because of this, we examined …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Brouns, F., Bjorck, I., Frayn, K. N., Gibbs, A. L., Lang, V., Slama, G., & Wolever, T. M. S. (2005) · Nutrition Research Reviews · doi:10.1079/nrr2005100 · Cited by 1,093
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
“However, at times of rapid change, mainly due to blood flow variability, levels from alternate sites differ considerably.(12,13) Capillary blood glucose measured from the forearm is lower than fingertip values at times of rapid increases (>2 mg=dL=min) in systemic blood and higher during rapid decreases.”
Self-Monitoring of Blood Glucose: The Basics
Benjamin, E. M. (2002) · Clinical Diabetes · doi:10.2337/diaclin.20.1.45 · Cited by 159
Ellison, J. M., Stegmann, J. M., Colner, S. L., Michael, R. H., Sharma, M. K., Ervin, K. R., & Horwitz, D. L. (2002) · Diabetes Care · doi:10.2337/diacare.25.6.961 · Cited by 133
“Recently, Koschinsky and Jungheim (7) compared forearm and finger capillary blood samples from patients with type 1 diabetes.”
Background
Metadata
- Authors
- Jungheim, K., & Koschinsky, T.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2001-07-01
- Volume
- 24
- Issue
- 7
- Pages
- 1303-1304
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1997863982
- Cited by
- 62
- References
- 0
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Risky Delay of Hypoglycemia Detection by Glucose Monitoring at the Arm. https://app.cochat.ai/papers/10.2337/diacare.24.7.1303-a
- The paper
- Jungheim, K., & Koschinsky, T. (2001). Risky Delay of Hypoglycemia Detection by Glucose Monitoring at the Arm. Diabetes Care. https://doi.org/10.2337/diacare.24.7.1303-a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.