To Pump or Not to Pump
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
First fully described in 1983, intensive insulin therapy attempts to match the levels of insulin in the blood with the physiologic needs of the diabetic patient (1). The results of the Diabetes Control and Complications Trial solidified the importance of this approach to the prevention of microvascular complications of diabetes (2). There are two primary approaches to intensive insulin therapy: 1 ) multiple daily injections (MDI), and 2 ) continuous subcutaneous insulin infusion utilizing an external insulin infusion pump (CSII). For the last 10 years, a scientific (and often emotional) debate has existed concerning which approach is superior. The answer is important, as it affects the lifestyle, financial reserves, safety, and glucose control of the diabetic patient. Subcutaneous insulin does not reproduce the physiological delivery of insulin to the liver and systemic circulation. In humans, insulin is secreted directly into the hepatic portal vein such that the liver is exposed to higher concentrations of insulin compared with the systemic circulation. The liver subsequently removes ∼50% of this insulin, thereby lowering the exposure of the peripheral tissues to insulin. This differential insulin exposure has physiological ramifications, resulting in very fine control of intermediary metabolism. In contrast, both CSII and MDI deliver insulin subcutaneously, bypassing the liver and entering the systemic circulation. However, an insulin pump has one unique advantage over insulin injections: the ability to program changes in basal insulin dosage to meet an anticipated increase or decrease in need. This feature can be advantageous in controlling the normal rise in blood glucose concentration before breakfast (i.e., the dawn phenomenon) or preventing anticipated hypoglycemia from exercise or fasting. The ability to set basal profiles has been considered to be the major benefit of the CSII, but a recent study demonstrates that the use of the “dual wave” and “square wave” bolus delivery significantly …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lepore, M., Pampanelli, S., Fanelli, C., Porcellati, F., Bartocci, L., Di Vincenzo, A., Cordoni, C., Costa, E., Brunetti, P., & Bolli, G. B. (2000) · Diabetes · doi:10.2337/diabetes.49.12.2142 · Cited by 818
Chase, H. P., Saib, S. Z., MacKenzie, T., Hansen, M. M., & Garg, S. K. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00685.x · Cited by 116
Cited by
Glycemic Parameters with Multiple Daily Injections Using Insulin Glargine Versus Insulin Pump
Garg, S. K., Walker, A. J., Hoff, H. K., D'Souza, A. O., Gottlieb, P. A., & Chase, H. P. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504322783350 · Cited by 60
Piras de Oliveira, C., Mitchell, B. D., Fan, L., Garey, C., Liao, B., Bispham, J., Vint, N., Perez-Nieves, M., Hughes, A., & McAuliffe-Fogarty, A. (2021) · Current Medical Research and Opinion · doi:10.1080/03007995.2020.1843423 · Cited by 9
Metadata
- Authors
- Schade, D. S., & Valentine, V.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2002-11-01
- Volume
- 25
- Issue
- 11
- Pages
- 2100-2102
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2052101261
- Cited by
- 37
- References
- 2
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: To Pump or Not to Pump. https://app.cochat.ai/papers/10.2337/diacare.25.11.2100
- The paper
- Schade, D. S., & Valentine, V. (2002). To Pump or Not to Pump. Diabetes Care. https://doi.org/10.2337/diacare.25.11.2100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.