CoChat

Reduction of Blood Glucose Variability in Type 1 Diabetic Patients Treated By Pancreatic Islet Transplantation

Open access
Kessler, Laurence, Passemard, Raphael, Oberholzer, Jose, Benhamou, Pierre Yves, Bucher, Pascal, Toso, Christian, Meyer, Pierre, Penfornis, Alfred, Badet, Lionel, Wolf, Philippe, Colin, Cyrille, Morel, Philippe, Pinget, Michel, on behalf of the GRAGIL Group · 2002 · Diabetes Care
Cited by 65

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE—To compare the glycemic profiles of patients with type 1 diabetes treated with either an implantable insulin pump or pancreas or islet transplantation by the means of the continuous glucose monitoring system (CGMS; Minimed, Sylmar, CA). RESEARCH DESIGN AND METHODS—The CGMS enabled recording of subcutaneous glucose concentrations (range 2.2–22 mmol/l) over 72 h (288 measurements per day). Over 3 days, 26 patients with type 1 diabetes were connected to a CGMS: 10 patients were treated with intraperitoneal insulin infusion through an implantable pump (IPII), 9 patients were treated with simultaneous pancreas-kidney transplantation (SPK), and 7 patients were treated with pancreatic islet transplantation after kidney grafting (IAK). All SPK patients and four IAK patients were insulin independent, whereas three IAK patients had partial graft function and reduced exogenous insulin needs. Glucose control was evaluated by the mean glucose concentration, glucose variability, and the number and duration of hypoglycemic events (<3.3 mmol/l) over 3 days. RESULTS—The mean glucose concentration and the glucose variability in SPK and IAK patients were significantly lower than those observed in patients treated with IPII: 5.38 ± 1.12 and 5.83 ± 0.81 vs. 7.81 ± 1.55 mmol/l (P < 0.001) and 1.40 ± 0.42 and 1.32 ± 0.53 vs. 3.47 ± 1.66 mmol/l (P < 0.001), respectively. Furthermore, the mean glucose concentration and the glucose variability were comparable between SPK and IAK patients. Over 3 days, no hypoglycemic events were observed in SPK patients and insulin-independent IAK patients. A total of 4.12 ± 1.66 hypoglycemic events were detected in the IPII patient group, whereas only 0.66 ± 0.57 events were observed in IAK patients with partial graft function (P < 0.001). The duration of the hypoglycemic events was significantly longer in IPII patients as compared with IAK patients: 64 ± 33 vs. 30 ± 15 min for the day period and 130 ± 62 vs. 30 ± 27 min for the night period (P < 0.001). CONCLUSIONS—Use of subcutaneous CGMS confirms that islet transplantation can be as efficient as pancreas transplantation in restoring good metabolic control and reducing blood glucose variability. Metabolic improvement due to use of an implantable insulin pump requires insulin delivery by a closed loop.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.25.12.2256

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 65

Metadata

Authors
Kessler, L., Passemard, R., Oberholzer, J., Benhamou, P. Y., Bucher, P., Toso, C., Meyer, P., Penfornis, A., Badet, L., Wolf, P., Colin, C., Morel, P., Pinget, M., & on behalf of the GRAGIL Group
Venue
Diabetes Care
Published
2002-12-01
Volume
25
Issue
12
Pages
2256-2262
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W1969333195
Cited by
65
References
1
FWCI
2.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction of Blood Glucose Variability in Type 1 Diabetic Patients Treated By Pancreatic Islet Transplantation. https://app.cochat.ai/papers/10.2337/diacare.25.12.2256
The paper
Kessler, L., Passemard, R., Oberholzer, J., Benhamou, P. Y., Bucher, P., Toso, C., Meyer, P., Penfornis, A., Badet, L., Wolf, P., Colin, C., Morel, P., Pinget, M., & on behalf of the GRAGIL Group. (2002). Reduction of Blood Glucose Variability in Type 1 Diabetic Patients Treated By Pancreatic Islet Transplantation. Diabetes Care. https://doi.org/10.2337/diacare.25.12.2256

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.