Dose Response of Inhaled Dry-Powder Insulin and Dose Equivalence to Subcutaneous Insulin Lispro
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—To determine the pharmacokinetic (PK) and glucodynamic (GD) dose response of human insulin inhalation powder (HIIP) delivered via AIR particle technology and dose equivalence to subcutaneous (SC) insulin lispro. RESEARCH DESIGN AND METHODS—Twenty healthy, nonsmoking, male or female subjects (aged 29.6 ± 6.9 years, BMI 23.2 ± 2.3 kg/m2, means ± SD) with normal forced vital capacity and forced expiratory volume were enrolled in an open-label, randomized, seven-period, euglycemic glucose clamp, cross-over trial. Each subject received up to four single doses of HIIP (2.6, 3.6, 5.2, or 7.8 mg) and three doses of SC lispro (6, 12, or 18 units) from 5 to 18 days apart. RESULTS—HIIP demonstrated a similar rapid onset but an extended time exposure and a prolonged duration of effect (late t50% 412 vs. 236 min, P < 0.001) compared with SC lispro. The HIIP versus SC lispro doses of 2.6 mg vs. 6 units, 5.2 mg vs. 12 units, and 7.8 mg vs. 18 units achieved similar PK area under the serum immunoreactive insulin (IRI) concentration-versus-time curve from time zero until the serum IRI concentrations returned to the predose baseline value [AUC(0-t′)] and GD (Gtot) responses. The median insulin (tmax) was not different between HIIP and SC lispro (45 min for both), although the median time of return to baseline for PK was apparently longer for HIIP compared with SC lispro (480 vs. 360 min). Relative bioavailability and relative biopotency of HIIP were consistent across doses (8 and 9%). CONCLUSIONS—While the time-action profile was longer for HIIP than for SC lispro, both treatments showed rapid initial absorption and similar overall PK exposure and GD effect. HIIP was as well tolerated as SC lispro, thereby offering a promising alternative to injectable insulin therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Variability of Insulin Absorption and Insulin Action
Heinemann, L. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502320798312 · Cited by 267
Self-citation
Cited by
Pharmaceutical Particle Engineering via Spray Drying
Vehring, R. (2008) · Pharmaceutical Research · doi:10.1007/s11095-007-9475-1 · Cited by 1,691
Current challenges in non-invasive insulin delivery systems: A comparative review
Khafagy, E.-S., Morishita, M., Onuki, Y., & Takayama, K. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.019 · Cited by 436
Insulin structure and function
Mayer, J. P., Zhang, F., & DiMarchi, R. D. (2007) · Peptide Science · doi:10.1002/bip.20734 · Cited by 230
Arnolds, S., Kuglin, B., Kapitza, C., & Heise, T. (2010) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2010.02470.x · Cited by 69
de la Peña, A., Seger, M., Soon, D., Scott, A. J., Reddy, S. R., Dobbins, M. A., Brown‐Augsburger, P., & Linnebjerg, H. (2016) · Clinical Pharmacology in Drug Development · doi:10.1002/cpdd.221 · Cited by 67
Self-citation
Metadata
- Authors
- Rave, K. M., Nosek, L., de la Peña, A., Seger, M., Ernest, C. S., Heinemann, L., Batycky, R. P., & Muchmore, D. B.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2005-10-01
- Volume
- 28
- Issue
- 10
- Pages
- 2400-2405
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2064532612
- Cited by
- 75
- References
- 1
- FWCI
- 10.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dose Response of Inhaled Dry-Powder Insulin and Dose Equivalence to Subcutaneous Insulin Lispro. https://app.cochat.ai/papers/10.2337/diacare.28.10.2400
- The paper
- Rave, K. M., Nosek, L., de la Peña, A., Seger, M., Ernest, C. S., Heinemann, L., Batycky, R. P., & Muchmore, D. B. (2005). Dose Response of Inhaled Dry-Powder Insulin and Dose Equivalence to Subcutaneous Insulin Lispro. Diabetes Care. https://doi.org/10.2337/diacare.28.10.2400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.