The DOI matches its Crossref record.
Affinity Sensor: A New Technique for Developing Implantable Sensors for Glucose and Other Metabolites
Abstract
We describe affinity sensors for monitoring various metabolites in blood plasma by optical means. The principle of detection is similar to that used in radioimmunoassays and is based on the competitive binding of a particular metabolite and a fluorescein-labeled analogue with receptor sites specific for the metabolite and the labeled ligand. This concept has been directed toward the development of an affinity sensor for glucose. Concanavalin A, a protein with specific binding character for glucose, was immobilized on the inside surface of a hollow dialysis fiber. Fluorescein-labeled dextran was selected as the competitive labeled ligand. The molecular weight cutoff of the dialysis fiber is low enough to completely retain the 70,000 MW dextran within the fiber lumen while glucose can freely pass through the dialysis membrane. The sensor is completed by inserting a single optical fiber in the lumen of the dialysis fiber, thus allowing measurement of the unbound FITC-dextran. Preliminary tests of the sensor indicated the feasibility of the approach. Sensitivity to glucose in the physiologic range was obtained, but further work will be required to optimize the sensitivity and response time of the sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Borisov, S. M., & Wolfbeis, O. S. (2008) · Chemical Reviews · doi:10.1021/cr068105t · Cited by 1,018
Fiber-Optic Sensors for Biomedical Applications
Peterson, J. I., & Vurek, G. G. (1984) · Science · doi:10.1126/science.6422554 · Cited by 300
Biosensors and Microfluidic Biosensors: From Fabrication to Application
Kulkarni, M. B., Ayachit, N. H., & Aminabhavi, T. M. (2022) · Biosensors · doi:10.3390/bios12070543 · Cited by 281
Immunosensors: Antibody-based biosensors
North, J. R. (1985) · Trends in Biotechnology · doi:10.1016/0167-7799(85)90119-2 · Cited by 123
Ertefai, S., & Gough, D. A. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90097-6 · Cited by 52
Metadata
- Authors
- Schultz, J. S., Mansouri, S., & Goldstein, I. J.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1982-05-01
- Volume
- 5
- Issue
- 3
- Pages
- 245-253
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2005336425
- Cited by
- 305
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Affinity Sensor: A New Technique for Developing Implantable Sensors for Glucose and Other Metabolites. https://app.cochat.ai/papers/10.2337/diacare.5.3.245
- The paper
- Schultz, J. S., Mansouri, S., & Goldstein, I. J. (1982). Affinity Sensor: A New Technique for Developing Implantable Sensors for Glucose and Other Metabolites. Diabetes Care. https://doi.org/10.2337/diacare.5.3.245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.