Treatment of Drop Foot Using an Implantable Peroneal Underknee Stimulator
Open accessThe DOI matches its Crossref record.
Abstract
An implantable peroneal stimulator has been developed to improve the rehabilitation of the drop foot patients who cannot use or refuse the use of conventionally applied peroneal braces. The small size promotes convenient attachment on the stimulation site after a minor surgical intervention. During the past two years twenty implants have been applied. The influence of different stimulation parameters upon the correction of anomalies during walking has been studied using clinical and computer-supported assessment. Possible noxious effects on the peroneal nerve have been studied by measuring nerve conduction velocity. The stimulator is well accepted by patients. Clinical observations show a significant correction of equinovarus and improved gait.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
BION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
“Various implantable single-channel stimulators powered by radio-frequency (RF) fields have been developed for foot drop following stroke [6] [7] [8] [9] but they are not suitable for more general therapeutic use, which often requires separate control of several different muscles.”
BackgroundAgnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundConsiderations for Safety with Chronically Implanted Nerve Electrodes
Agnew, W. F., & McCreery, D. B. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05845.x · Cited by 184
Metadata
- Authors
- Strojnik, P., Acimovic, R., Vavken, E., Simic, V, & Stanic, U.
- Venue
- Journal of Rehabilitation Medicine
- Published
- 2020-06-18
- Volume
- 19
- Issue
- 1
- Pages
- 37-43
- ISSN
- 1650-1977 (ISSN-L)
- 1651-2081
- OpenAlex
- W4378234374
- Cited by
- 60
- References
- 0
- FWCI
- 0.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Treatment of Drop Foot Using an Implantable Peroneal Underknee Stimulator. https://app.cochat.ai/papers/10.2340/1650197787193743
- The paper
- Strojnik, P., Acimovic, R., Vavken, E., Simic, V, & Stanic, U. (2020). Treatment of Drop Foot Using an Implantable Peroneal Underknee Stimulator. Journal of Rehabilitation Medicine. https://doi.org/10.2340/1650197787193743
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.