Cited by 10Medical Device Sterilization and DisinfectionInfection Control in HealthcareAntimicrobial agents and applications

Affinity and Inactivation of Bacterial Endotoxins for Medical Device Materials

Open access
Kimble, Allan, Hauschild, James, McDonnell, Gerald·2023·Biomedical Instrumentation & Technology

Abstract

Endotoxins are high-molecular-weight complexes that contain lipopolysaccharide, protein, and phospholipid originating from the outer membrane of gram-negative bacteria. As gram-negative bacteria are naturally present in a variety of sources, endotoxins are commonly identified as contaminants in manufacturing environments. In industrial applications, endotoxin often is considered difficult to inactivate and to have a strong affinity with surfaces resulting from its hydrophobic chemical structure. This article describes the investigation of the true affinity of endotoxin, from various microbial sources in solution, for medical device material surfaces. In addition, endotoxin reduction was investigated with commonly used sterilization methods such as those based on ionizing radiation, dry and moist heat, and ethylene oxide sterilization. Endotoxin activity was found to be reduced following exposure to a range of sterilization modalities with the degree of activity reduction related to the source of endotoxin and the substrate material upon which it was present.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2345/0899-8205-57.4.153

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Residual microbial components, particularly endotoxins such as LPS, are among the most potent inducers of innate immune activation; even trace amounts can activate TLR4 signaling in APCs, leading to pro-inflammatory cytokines and M1-like macrophage polarization.

    “Residual microbial components introduced or not properly removed during processing, particularly endotoxins such as lipopolysaccharides (LPS), are among the most potent inducers of innate immune activation [145].Even trace amounts of LPS can activate TLR4 signaling in APCs, leading to robust secretion of pro-inflammatory cytokines and skewing macrophage polarization toward an M1-like phenotype.”

    From Immune Response to Extracellular Matrix Bioscaffolds: A Comprehensive Review (2025) · cites this paper as [145]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. Hagel L, Jagschies G, Sofer G. Analysis. In: Hagel L, Jagschies G, Sofer G, Eds. Handbook of Process Chromatography. 2nd ed. Cambridge, MA: Aca- demic Press; 2008:133.
  2. Lieder R, Petersen PH, Sigurjónsson ÓE. Endo- toxins: invisible companion in biomaterials re- search. Tissue Eng Part B Rev. 2013;19(5):391-402.

Cited by

Sorted by citations

Authors
Kimble, A., Hauschild, J., & McDonnell, G.
Affiliations
Johnson & Johnson (United States) (US)
Venue
Biomedical Instrumentation & Technology
Published
2023-10
Volume
57
Issue
4
Pages
153-162
ISSN
  • 0899-8205 (ISSN-L)
  • 1943-5967
OpenAlex
W4390552906
Cited by
10
References
25
Citations by year
2026: 3 · 2025: 4 · 2024: 3
FWCI
1.82
Type
journal article
Language
en
Open access
Locations
  • Biomedical Instrumentation & Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
  • Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
  • Physical Sciences › Chemistry › Organic Chemistry › Antimicrobial agents and applications
Keywords
bacterial endotoxin, lipopolysaccharide, medical device materials, surface adsorption, endotoxin inactivation, sterilization, ionizing radiation sterilization, dry heat sterilization, autoclaving, ethylene oxide sterilization, Gram-negative bacteria, microbial contamination
MeSH terms
Endotoxins, Hot Temperature, Sterilization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review