The DOI matches its Crossref record.
The International Committee of Medical Journal Editors
Abstract
Purpose: To investigate the dosimetric accuracy of the sliding window gated IMRT compared with the static treatment, using varying dose rates.Materials and methods: This study measured changes in output and diode array response with changing dose rate, verified the precision of the motion table, and measured changes in dose distribution accuracy with film and diodes at two depths with changing dose rate.During 4DCT (4 Dimensional Computed Tomography), the patient's respiratory signals and target motion were recorded and imported to the XY4D simulation table of SUN NUCLEAR Corporation to simulate the patient's respiration and tumour motion.A single field of each sliding window IMRT plan with 30º wedge and one for lung cancer were used in this study.Three irradiating conditions, static and moving target with and without gating, were applied to both plans.Results: The standard deviations of output, with the dose rates changing from 300-600 MU/min, were 0.065 cGy and 0.169 cGy for the ionisation chamber and diode, respectively.The verification of the motion table shows very good precision with 9.98 ± 0.02 cm (true value = 10.0 cm).The measurements by MapCheck show the gamma index of the planned absolute dose distribution in static and moving targets with gating, resulting in more than 96% passing for all dose rates.The absolute dose distribution measured by film for the static target was agreeable with the value of moving target with gating. Conclusion:The sliding window gated IMRT technique is able to deliver an accurate dose to a moving target with the dose rate of 300-600 MU/min that is suitable for clinical treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
CONSORT 2010 statement: extension to randomised pilot and feasibility trials
on behalf of the PAFS consensus group, Eldridge, S. M., Chan, C. L., Campbell, M. J., Bond, C. M., Hopewell, S., Thabane, L., & Lancaster, G. A. (2016) · Pilot and Feasibility Studies · doi:10.1186/s40814-016-0105-8 · Cited by 2,843
Sex and Gender Equity in Research: rationale for the SAGER guidelines and recommended use
Heidari, S., Babor, T. F., De Castro, P., Tort, S., & Curno, M. (2016) · Research Integrity and Peer Review · doi:10.1186/s41073-016-0007-6 · Cited by 2,184
Metadata
- Authors
- van der Weyden, M.
- Venue
- Proceedings of the Workshop on Publishing for Biomedical Journal Editors and Reviewers
- Published
- 2006
- OpenAlex
- W2319729735
- Cited by
- 1,998
- References
- 0
- FWCI
- 129.63
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The International Committee of Medical Journal Editors. https://app.cochat.ai/papers/10.2349/biij.2.4.e54-13
- The paper
- van der Weyden, M. (2006). The International Committee of Medical Journal Editors. Proceedings of the Workshop on Publishing for Biomedical Journal Editors and Reviewers. https://doi.org/10.2349/biij.2.4.e54-13
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.