Do in vivo terahertz imaging systems comply with safety guidelines?
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Techniques for the coherent generation and detection of electromagnetic radiation in the far infrared, or terahertz, region of the electromagnetic spectrum have recently developed rapidly and may soon be applied for in vivo medical imaging. Both continuous wave and pulsed imaging systems are under development, with terahertz pulsed imaging being the more common method. Typically a pump and probe technique is used, with picosecond pulses of terahertz radiation generated from femtosecond infrared laser pulses, using an antenna or nonlinear crystal. After interaction with the subject either by transmission or reflection, coherent detection is achieved when the terahertz beam is combined with the probe laser beam. Raster scanning of the subject leads to an image data set comprising a time series representing the pulse at each pixel. A set of parametric images may be calculated, mapping the values of various parameters calculated from the shape of the pulses. A safety analysis has been performed, based on current guidelines for skin exposure to radiation of wavelengths 2.6 μm–20 mm (15 GHz–115 THz), to determine the maximum permissible exposure (MPE) for such a terahertz imaging system. The international guidelines for this range of wavelengths are drawn from two U.S. standards documents. The method for this analysis was taken from the American National Standard for the Safe Use of Lasers (ANSI Z136.1), and to ensure a conservative analysis, parameters were drawn from both this standard and from the IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (C95.1). The calculated maximum permissible average beam power was 3 mW, indicating that typical terahertz imaging systems are safe according to the current guidelines. Further developments may however result in systems that will exceed the calculated limit. Furthermore, the published MPEs for pulsed exposures are based on measurements at shorter wavelengths and with pulses of longer duration than those used in terahertz pulsed imaging systems, so the results should be treated with caution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subpicosecond photoconducting dipole antennas
Smith, P. R., Auston, D. H., & Nuss, M. C. (1988) · IEEE Journal of Quantum Electronics · doi:10.1109/3.121 · Cited by 805
Cited by
Terahertz Technology in Biology and Medicine
Siegel, P. H. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.835916 · Cited by 1,378
Terahertz spectroscopy of explosives and drugs
Davies, A. G., Burnett, A. D., Fan, W., Linfield, E. H., & Cunningham, J. E. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70016-6 · Cited by 569
Terahertz pulsed spectroscopy of freshly excised human breast cancer
Ashworth, P. C., Pickwell-MacPherson, E., Provenzano, E., Pinder, S. E., Purushotham, A. D., Pepper, M., & Wallace, V. P. (2009) · Optics Express · doi:10.1364/oe.17.012444 · Cited by 479
Terahertz Pulsed Imaging of Human Breast Tumors
Fitzgerald, A. J., Wallace, V. P., Jimenez-Linan, M., Bobrow, L., Pye, R. J., Purushotham, A. D., & Arnone, D. D. (2006) · Radiology · doi:10.1148/radiol.2392041315 · Cited by 396
Self-citationIn vivo study of human skin using pulsed terahertz radiation
Pickwell, E., Cole, B. E., Fitzgerald, A. J., Pepper, M., & Wallace, V. P. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/9/001 · Cited by 381
Self-citation
Metadata
- Authors
- Berry, E., Walker, G. C., Fitzgerald, A. J., Zinov’ev, N. N., Chamberlain, M., Smye, S. W., Miles, R. E., & Smith, M. A.
- Venue
- Journal of Laser Applications
- Publisher
- Laser Institute of America
- Published
- 2003-07-17
- Volume
- 15
- Issue
- 3
- Pages
- 192-198
- ISSN
- 1042-346X (ISSN-L)
- 1938-1387
- OpenAlex
- W2073115783
- Cited by
- 103
- References
- 1
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.