Impact of grid-forming control on the internal energy of a modular multilevel converter
The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Abstract
This paper presents a comparative analysis regarding the dynamic behavior of a Modular Multi-level Converter (MMC) with grid-forming control either with or without controlling the MMC internal energy. It has been demonstrated that the internal energy of the MMC in low-level control interacts with the high-level control, which is performed by a grid-forming scheme. In case of controlling the internal energy of the MMC, this interaction is mitigated. Moreover, it has been shown that the dynamic behavior of a grid-forming controlled MMC with internal energy control is identical to an equivalent 2-level Voltage Source Converter (VSC).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Steady-State Analysis Method for a Modular Multilevel Converter
Song, Q., Liu, W., Li, X., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227818 · Cited by 503 · cited 1×
“1-a, is the preferred topology for VSC-based HVDC systems in high power applications due to the low power losses, low harmonics and high scalability [9].”
BackgroundBergna, G., Berne, E., Egrot, P., Lefranc, P., Arzande, A., Vannier, J.-C., & Molinas, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2225397 · Cited by 267 · cited 1×
“More details about the CCSC are given in [10].”
BackgroundTuning of Cascaded Controllers for Robust Grid-Forming Voltage Source Converter
Qoria, T., Gruson, F., Colas, F., Guillaud, X., Debry, M.-S., & Prévost, T. (2018) · Power Systems Computation Conference · doi:10.23919/pscc.2018.8443018 · Cited by 145
Self-citationImproving Small-Signal Stability of an MMC With CCSC by Control of the Internally Stored Energy
Freytes, J., Bergna‐Diaz, G., Suul, J. A., D’Arco, S., Gruson, F., Colas, F., Saad, H., & Guillaud, X. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2725579 · Cited by 117 · cited 1×
“Each arm consists of an aggregated capacitance , an inductance and an equivalent resistance [2].”
BackgroundSelf-citationRokrok, E., Qoria, T., Bruyère, A., François, B., & Guillaud, X. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106765 · Cited by 77 · cited 2×
“More details about this grid-forming control are given in [14], [15].”
BackgroundSelf-citationMMC Stored Energy Participation to the DC Bus Voltage Control in an HVDC Link
Samimi, S., Gruson, F., Delarue, P., Colas, F., Belhaouane, M. M., & Guillaud, X. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2540926 · Cited by 58 · cited 1×
“The MMC control has been widely studied in the literature mostly with the grid-following scheme in the high-level control [1]–[3].”
BackgroundSelf-citationTayyebi, A., Dörfler, F., Kupzog, F., Miletic, Z., & Hribernik, W. (2018) · CIRED · doi:10.34890/412 · Cited by 57 · cited 1×
“Several grid-forming control strategies have been proposed in the literature [11]–[13].”
BackgroundFrequency support from modular multilevel converter based multi-terminal HVDC schemes
Adeuyi, O. D., Cheah-Mane, M., Liang, J., Jenkins, N., Wu, Y., Li, C., & Wu, X. (2015) · 2015 IEEE Power & Energy Society General Meeting · doi:10.1109/pesgm.2015.7286086 · Cited by 56 · cited 1×
“The first examples of studying the utilization of the grid-forming control for the MMC have been published in [5], [6] with the aim of providing virtual inertia and frequency support for an MMC-based HVDC terminal.”
BackgroundEffect of Using PLL-Based Grid-Forming Control on Active Power Dynamics Under Various SCR
Rokrok, E., Qoria, T., Bruyère, A., François, B., & Guillaud, X. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927648 · Cited by 55 · cited 3×
“The frequency of this three-phase signal in steady state is equal to the grid nominal frequency [14].”
BackgroundSelf-citationEnergetic macroscopic representation and inversion based control of a modular multilevel converter
Delarue, P., Gruson, F., & Guillaud, X. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6631859 · Cited by 49 · cited 1×
“= + ), the variation in the average value of the energy variables ( , ) are expressed as follow [4], [17]: ≈ − (13) ≈ −2 ∗< > , (14) where = is the total injected AC power of the MMC.”
BackgroundSelf-citation
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“the MMC impacts the dynamic behavior while operated with grid-forming control [87].”
BackgroundGrid Forming Inverters: A Review of the State of the Art of Key Elements for Microgrid Operation
Anttila, S., Döhler, J. S., Oliveira, J. G., & Boström, C. (2022) · Energies · doi:10.3390/en15155517 · Cited by 180
“In addition, it is a very used topology when the objective is the application of converters in a high-power system [67].”
BackgroundQoria, T., Wu, H., Wang, X., & Colak, I. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3232987 · Cited by 140
“This assumption has been justified in [18] and will also be checked in this paper through time-domain simulations.”
BackgroundSelf-citationGrid-forming control to achieve a 100% power electronics interfaced power transmission systems
Qoria, T. (2020) · theses.fr (ABES) · doi:10.70675/6a9eeb3aze350z4a47zbbd3zea3bb935e362 · Cited by 68
Self-citationCardozo, C., Prévost, T., Huang, S.-H. F., Lu, J., Modi, N., Hishida, M., Li, X., Abdalrahman, A., Samuelsson, P., Cutsem, T. V., et al. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110855 · Cited by 50
Self-citationArévalo-Soler, J., Sánchez‐Sánchez, E., Prieto‐Araujo, E., & Gomis‐Bellmunt, O. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108369 · Cited by 23
Mourouvin, R., Filliot, L., Ghyselinck, A., Dai, J., Bacha, S., Georges, D., & Benchaib, A. (2023) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2023.3270744 · Cited by 14
“High Voltage Direct Current (HVDC) systems and applied to Modular Multilevel Converters (MMCs) [4], [5], [6], where this converter topology is expected to play a major role in”
MethodStability Analysis of Grid-Forming MMC-HVDC Transmission Connected to Legacy Power Systems
Lourenço, L. F. N., Perez, F., Iovine, A., Damm, G., Monaro, R. M., & Salles, M. B. C. (2021) · Energies · doi:10.3390/en14238017 · Cited by 16
“A wide variety of GFM strategies were proposed in the technical literature: the virtual synchronous machine (VSM) [22,23], the synchronverter [24–26], droop control [27,28], and others that were reviewed in [21].”
Nonlinear Controller for MMC-HVdc Operating in Grid-Forming Mode
Lourenço, L. F. N., Iovine, A., Damm, G., & Filho, A. J. S. (2024) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2024.3467808 · Cited by 16
“The importance of the internal energy control for MMCs operating in GFM control was furthered investigated in [35], where the internal energy control is shown to be able to mitigate the interactions between the inner and outer control loops.”
Control of MMC-based Grid-Forming STATCOM with DC supercapacitors for energy storage
Avdiaj, E., & Beerten, J. (2023) · IEEE PowerTech Conference · doi:10.1109/powertech55446.2023.10202963 · Cited by 15
“The overall control structure is explained in [13], and the difference energy control is based on [14].”
BackgroundFrequency-Adaptive Energy Control for Grid-Forming MMCs Under Unbalanced Conditions
Avdiaj, E., D’Arco, S., Piegari, L., & Suul, J. A. (2023) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2023.3302707 · Cited by 13
Pairing grid-forming VSC filter topologies with voltage control structures
Girona‐Badia, J., Prieto‐Araujo, E., & Gomis‐Bellmunt, O. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109670 · Cited by 12
Testing Requirements and Control Strategies of Next-Generation Grid Emulator: A Review
Li, Z., Ponnaganti, P., Zhao, F., Wang, X., Bak‐Jensen, B., Munk‐Nielsen, S., & Blaabjerg, F. (2022) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-himeji2022-ecce53331.2022.9807056 · Cited by 10
“The combination of energy-based internal control and grid-forming based external control of MMC is discussed in [45], [46].”
BackgroundA Review on Multi-Terminal High Voltage Direct Current Networks for Wind Power Integration
Lourenço, L. F. N., Louni, A., Damm, G., Netto, M., Drissi‐Habti, M., Grillo, S., Filho, A. J. S., & Meegahapola, L. G. (2022) · Energies · doi:10.3390/en15239016 · Cited by 9
“The control problem of an MMC acting as a Grid-Forming Converter is a challenging task that is currently under investigation by the scientific community (see [41–44]).”
Avdiaj, E., Suul, J. A., D’Arco, S., & Piegari, L. (2022) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe-powereng54966.2022.9880890 · Cited by 4
Design of a Single Branch of Energy Storage Submodules Connected to HVDC Systems to Support AC Grids
Errigo, F., Sau-Bassols, J., Bekkouri, H., Morel, F., Gonzalez‐Torres, J. C., Benchaib, A., Rault, P., & Bourgeat, X. (2024) · Electronics · doi:10.3390/electronics13173355 · Cited by 2
Kamalinejad, K., Mohtat, S., & Zamani, A. R. (2025) · Energy Conversion Congress and Expo Europe (ECCE Europe) · doi:10.1109/ecce-europe62795.2025.11238501 · Cited by 1
“However, as grid-forming (GFM) control schemes gain attention for providing ancillary services such as inertia support in power systems, their adaptation to MMCs is expected [3].”
Viatkin, A. (2023) · Springer theses · doi:10.1007/978-3-031-24712-5_1
Impact of Submodule Energy Balancing on Grid Emulation Performance of Modular Multilevel Converters
Jia, M., Bach, A., Mathé, J., Ma, Z., von den Hoff, D., & Doncker, R. W. D. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567363
“On the other hand, Rokrok investigated the impact of internal energy balancing control on the operation of an MMC [4].”
Background
Metadata
- Authors
- Rokrok, E., Qoria, T., Bruyere, A., Francois, B., Zhang, H., Belhaouane, M., & Guillaud, X.
- Affiliations
- Arts et Métiers (FR)
- Venue
- 2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)
- Publisher
- IEEE
- Published
- 2020-09
- Pages
- 1-10
- OpenAlex
- W3091770914
- Semantic Scholar
- ae3581827985825b2dc1ed558fe76fa248afe1cf
- Cited by
- 19
- References
- 19
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 5 · 2022: 6 · 2021: 2 · 2020: 1
- FWCI
- 4.92
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- European Conference on Power Electronics and Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- modular multilevel converter, grid-forming control, voltage source converter, converter dynamic behavior, power converters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.