Comparative experimental analysis of the quality-of-service and energy-efficiency of VMs and containers' consolidation for cloud applications
Open accessThe DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.
Abstract
The consolidation of services is a widely accepted technique for IaaS Cloud providers to reducing energy consumption and improving the utilization of their resources. This technique is based on distributing all services in the minimum amount of servers. This way, the overall energy consumption of the datacenter is reduced, as less servers are needed to be active. Traditionally, research has focused on strategies for consolidation of Virtual Machines (VMs), but containers are changing the landscape of Cloud services. Containers are expected to optimize the consolidation of services by reducing the amount of needed resources, thus allocating more services using less servers. However, while multiple research works have been produced in the Energy Efficiency (EE) achieved through consolidation of VMs, there is yet no experimental work on how consolidation of containers affects EE, when assuming a given Quality-of-Service (QoS) to the user. In this paper we show an experimental analysis on the effects of consolidation of containers in the QoS and EE, compared to the consolidation of VMs. We demonstrate that the consolidation of containers is indeed more optimal than the one of VMs, both in terms of QoS and EE. Consecutively, we analyze how the degradation of the service is produced both in QoS and EE, and we show how QoS is the variable which is more affected by consolidation. This work provides the necessary scientific background on consolidation of two widely used virtualization technologies, and we believe it is useful for future works on the optimization of resources in datacenters.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Docker, when configured to a maximum latency of 3000ms, can operate up to 21% more services than KVM.”
From Energy efficiency in cloud computing data centers: a survey on software technologies (2023) · cites this paper as [39]
In the citing paper
“Docker provides this service in this setup while consuming 11.33% less energy than KVM [39].”
From Energy efficiency in cloud computing data centers: a survey on software technologies (2023) · cites this paper as [39]
Citations
Cites
Armbrust, M., Fox, A., Griffith, R., Joseph, A. D., Katz, R., Konwinski, A., Lee, G., Patterson, D., Rabkin, A., Stoica, I., et al. (2010) · Communications of the ACM · doi:10.1145/1721654.1721672 · Cited by 9,464 · cited 1×
“This way, they consolidate services on several active servers, thus using less resources [3].”
An updated performance comparison of virtual machines and Linux containers
Felter, W., Ferreira, A., Rajamony, R., & Rubio, J. (2015) · 2015 IEEE International Symposium on Performance Analysis of Systems and Software (ISPASS) · doi:10.1109/ispass.2015.7095802 · Cited by 1,054 · cited 1×
“[9] showed that the utilization of containers has a lighter weight on CPU than using VMs.”
Zhang, Z. (1995) · Information Processing & Management · doi:10.1016/0306-4573(95)80026-p · Cited by 668
The architecture of virtual machines
Smith, J. E., & Nair, R. (2005) · Computer · doi:10.1109/mc.2005.173 · Cited by 574
Gunaratne, C., Christensen, K., & Nordman, B. (2005) · International Journal of Network Management · doi:10.1002/nem.565 · Cited by 287
Performance Comparison Analysis of Linux Container and Virtual Machine for Building Cloud
Seo, K.-T., Hwang, H.-S., Moon, I.-Y., Kwon, O.-Y., & Kim, B.-J. (2014) · Advanced science and technology letters · doi:10.14257/astl.2014.66.25 · Cited by 133
Cooling Energy-Hungry Data Centers
Meijer, G. I. (2010) · Science · doi:10.1126/science.1182769 · Cited by 126 · cited 1×
“4% of electricity worldwide with a global economic impact of $30 billion [2].”
Trends and challenges in cloud datacenters
Bilal, K., Malik, S. U. R., Khan, S. U., & Zomaya, A. Y. (2014) · IEEE Cloud Computing · doi:10.1109/mcc.2014.26 · Cited by 109 · cited 1×
“On the one hand, the increase in demand of resources and the growing number of users have defined new challenges to current IaaS Cloud datacenters, such as QoS for the clients or scalability of their infrastructures [1].”
Power Consumption of Virtualization Technologies: An Empirical Investigation
Morabito, R. (2015) · IEEE/ACM International Conference on Utility and Cloud Computing (UCC) · doi:10.1109/ucc.2015.93 · Cited by 104 · cited 2×
“In 2015, Morabito [10] performed several experiments using different dedicated benchmarks (CPU intensive; memory intensive; and network intensive) on the power”
On Consistency and Network Latency in Distributed Interactive Applications: A Survey—Part I
Delaney, D. T., Ward, T. E., & McLoone, S. (2006) · PRESENCE Virtual and Augmented Reality · doi:10.1162/pres.2006.15.2.218 · Cited by 96 · cited 1×
“contributing factor to spatial and temporal inconsistencies experienced by end users in the virtual world” [15].”
User Preference and Search Engine Latency
Brutlag, J. D., Hutchinson, H. B., & Stone, M. V. (2008) · Cited by 61
GUI Bloopers: Don'ts and Do's for Software Developers and Web Designers
Johnson, J. A. (2000) · Medical Entomology and Zoology · Cited by 59
Linux-based virtualization for HPC clusters
Nussbaum, L., Anhalt, F., Mornard, O., & Gelas, J.-P. (2009) · Cited by 35
An experiment-driven energy consumption model for virtual machine management systems
Callau-Zori, M., Samoila, L., Orgerie, A., & Pierre, G. (2017) · Sustainable Computing Informatics and Systems · doi:10.1016/j.suscom.2017.11.001 · Cited by 25 · cited 2×
“Also, no work in literature offers an empirical limit of containers running on the same physical machine, as it has been already addressed for VMs [4].”
Self-citationEnergy efficiency comparison of hypervisors
Jiang, C., Ou, D., Wang, Y., You, X., Zhang, J., Wan, J., Luo, B., & Shi, W. (2016) · International Green and Sustainable Computing Conference · doi:10.1109/igcc.2016.7892607 · Cited by 24 · cited 1×
“[11].”
GRaNADA: A Network-Aware and Energy-Efficient PaaS Cloud Architecture
Cuadrado-Cordero, I., Orgerie, A., & Morin, C. A. (2015) · IEEE International Conference on Data Science and Data Intensive Systems · doi:10.1109/dsdis.2015.65 · Cited by 8
Self-citation
Research works printed but not linked: 4
- 2017, Lyon:hardware - grid5000, Grid5000
- johnson, 2000, GUI bloopers donts and dos for software developers and Web designers
- consulting, 2009, Akamai Reveals 2 Seconds As the New Threshold of Acceptability for ECommerce Web Page Response Times
- 2016, Docker community passes two billion pulls!, ET Docker
Cited by
Energy efficiency in cloud computing data centers: a survey on software technologies
Katal, A., Dahiya, S., & Choudhury, T. (2023) · Cluster Computing · doi:10.1007/s10586-022-03713-0 · Cited by 516
“Docker, when configured to a maximum latency of 3000ms, can operate up to 21% more services than KVM. Docker provides this service in this setup while consuming 11.33% less energy than KVM [39].”
BackgroundInfluentialMavridis, I., & Karatza, H. D. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2018.12.035 · Cited by 122
Comprehensive Analysis of Container Technology
Siddiqui, T., Siddiqui, S. A., & Khan, N. A. (2019) · International Conference on Information Systems and Computer Networks (ISCON) · doi:10.1109/iscon47742.2019.9036238 · Cited by 33
“in [8] that containers provide a better QoS as compared to VMs because of its compact size which can consolidate more services with the same amount of resources.”
BackgroundA study on the evaluation of HPC microservices in containerized environment
Jha, D. N., Garg, S., Jayaraman, P. P., Buyya, R., Li, Z., Morgan, G., & Ranjan, R. K. (2019) · Concurrency and Computation Practice and Experience · doi:10.1002/cpe.5323 · Cited by 25
Green Containerized Service Consolidation in Cloud
Nath, S. B., Addya, S. K., Chakraborty, S., & Ghosh, S. K. (2020) · ICC 2020 - 2020 IEEE International Conference on Communications (ICC) · doi:10.1109/icc40277.2020.9149173 · Cited by 11
“The authors in [14] experimentally compared the performance of VMs and containers to show that the consolidation of containers perform better than the VM consolidation with respect to quality of service as well as energy.”
Background
Metadata
- Authors
- Cuadrado-Cordero, I., Orgerie, A.-C., & Menaud, J.-M.
- Affiliations
- Laboratoire des Sciences du Numérique de Nantes (FR)
- Venue
- 2017 25th International Conference on Software, Telecommunications and Computer Networks (SoftCOM)
- Publisher
- IEEE
- Published
- 2017-09
- Pages
- 1-6
- OpenAlex
- W2752628313
- Cited by
- 18
- References
- 17
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 5 · 2021: 1 · 2020: 4 · 2019: 3 · 2018: 1
- FWCI
- 1.68
- Type
- conference paper
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- International Conference on Software, Telecommunications and Computer Networks (SoftCOM) (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Physical Sciences › Computer Science › Information Systems › Cloud Computing and Resource Management
- Physical Sciences › Computer Science › Hardware and Architecture › Energy Efficiency in Computing
- Physical Sciences › Computer Science › Computer Networks and Communications › Distributed systems and fault tolerance
- Keywords
- virtual machine consolidation, container consolidation, quality of service, energy efficiency, cloud data centers, IAA, resource utilization, virtualization, service degradation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.