Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diffusion-weighted Imaging of Breast Cancer with the Sensitivity Encoding Technique: Analysis of the Apparent Diffusion Coefficient Value

Open access
KUROKI, Yoshifumi, NASU, Katsuhiro, KUROKI, Seiko, MURAKAMI, Koji, HAYASHI, Takayuki, SEKIGUCHI, Ryuzou, NAWANO, Shigeru·2004·Magnetic Resonance in Medical Sciences

Abstract

PURPOSE: The usefulness of diffusion-weighted imaging (DWI) in the field of neuroradiology has been established. Despite its high contrast resolution, DWI has the disadvantages of susceptibility artifact and chemical shift artifact. We performed DWI of breast cancer with the sensitivity encoding (SENSE) technique. METHODS: The subjects were 60 female patients with breast mass. All patients underwent MRI including SENSE-DWI and were diagnosed histologically. Of these patients, 55 were diagnosed with breast cancer and the remaining five were diagnosed with benign mass. The histological diagnoses of breast cancer were as follows: 39 cases of invasive ductal carcinoma (IDC); 11 cases of IDC with a predominant intraductal component and non IDC (pure or predominant NIDC); and five cases of special types of cancer. The MR system used was a Gyroscan Intera 1.5T (Philips Medical Systems). In addition to routine MRI for breast cancer, including contrast-enhanced dynamic, SENSE-DWI was obtained. The accuracy of the positional information of SENSE-DWI was visually compared with that of conventional images. The apparent diffusion coefficient (ADC) values of breast mass were analyzed with SENSE-DWI. RESULTS: The accuracy of positional information was adequate for diagnosing of all patients. The mean ADC value of breast cancer was 1.021x10(-3) mm2/s and that of benign mass was 1.488x10(-3) mm2/s (p=0.0002). The mean ADC value of IDC was 0.968x10(-3) mm2/s and that of pure or predominant NIDC was 1.218x10(-3) mm2/s (p=0.0011). CONCLUSION: SENSE-DWI was of sufficient quality to support diagnosis of breast mass. SENSE-DWI may permit the acquisition of more detailed information about lesions, including tumor cellularity, that is difficult to obtain with conventional techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2463/mrms.3.79

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 182

Metadata

Authors
KUROKI, Y., NASU, K., KUROKI, S., MURAKAMI, K., HAYASHI, T., SEKIGUCHI, R., & NAWANO, S.
Venue
Magnetic Resonance in Medical Sciences
Published
2004
Volume
3
Issue
2
Pages
79-85
ISSN
  • 1347-3182 (ISSN-L)
  • 1880-2206
OpenAlex
W2047274943
Cited by
182
References
1
FWCI
3.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.