Cited by 11Characterization and Applications of Magnetic NanoparticlesMagnetic Properties and Synthesis of FerritesGeomagnetism and Paleomagnetism Studies

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Synthesizing cysteine-coated magnetite nanoparticles as MRI contrast agent: Effect of pH and cysteine addition on particles size distribution

Ahmadi, R., Ranjbarnodeh, E., Gu, N.·2012·Materials Science-Poland

Abstract

Cysteine capped magnetite nanoparticles (10 to 20 nm) were synthesized via coprecipitation method under ultrasonic irradiation. The influence of pH value of the solution and cysteine addition on the size distribution and hydrodynamic size of nanoparticles were studied via TEM and PCS methods, respectively. The crystal structure and magnetic properties of the nanoparticles were characterized by XRD and VSM techniques, respectively. Coating density was calculated using TGA and TEM results. Cytotoxicity assessment performed by incubation of L929 cells, confirmed that ferrofluids are biocompatible. MRI studies conducted on rats demonstrated suitability of synthesized nanoparticles as contrast agents, especially for imaging of the lymph nodes.

Overview

Integrity signals

Registry

Crossref · 10.2478/s13536-012-0048-6

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Prototypic examples of materials used to coat iron oxide nanoparticles are polymers, fatty acids, amino acids, metals, and oxides.

    “Prototypic examples of materials used to coat iron oxide nanoparticles are polymers [28, 47, 50], fatty acids (like oleic acid, stearic acid, lauric acid and dodecylphosphonic acid) [51–55], amino acids (like phenyl alanine, tyrosine, arginine, lysine and cysteine) [56–58],_metals (like gold, gadolinium and silver) [59–61] and oxides (like silica and TiO2) [62–64].”

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Ahmadi, R., Ranjbarnodeh, E., & Gu, N.
Affiliations
  • Tehran University of Medical Sciences (IR)
  • Islamic Azad University, Tehran (IR)
Corresponding author
Ahmadi, R.
Venue
Materials Science-Poland
Published
2012-10-24
Volume
30
Issue
4
Pages
382-389
ISSN
  • 0137-1339 (ISSN-L)
  • 2083-1331
OpenAlex
W1999473860
Cited by
11
References
22
Citations by year
2026: 1 · 2025: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2019: 3 · 2018: 2
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
Materials Science-Poland (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
  • Physical Sciences › Materials Science › Materials Chemistry › Magnetic Properties and Synthesis of Ferrites
  • Physical Sciences › Earth and Planetary Sciences › Geophysics › Geomagnetism and Paleomagnetism Studies
Keywords
Fe3O4 nanoparticles, MRI contrast agents, ferrofluids, co-precipitation synthesis, sonication, pH effect, particle size distribution, hydrodynamic diameter, coating density, biocompatibility, cytotoxicity, lymph node imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review