The DOI matches its Crossref record.
Operating characteristics of transcritical CO2 heat pump for simultaneous water cooling and heating
Open accessAbstract
The effects of water-side operating conditions (mass flow rates and inlet temperatures) of both evaporator and gas cooler on the experimental as well as simulated performances (cooling and heating capacities, system coefficient of performance (COP) and water outlet temperatures) of the transcritical CO2 heat pump for simultaneous water cooling and heating the are studied and revised. Study shows that both the water mass flow rate and inlet temperature have significant effect on the system performances. Test results show that the effect of evaporator water mass flow rate on the system performances and water outlet temperatures is more pronounced (COP increases by 0.6 for 1 kg/min) compared to that of gas cooler water mass flow rate (COP increases by 0.4 for 1 kg/min) and the effect of gas cooler water inlet temperature is more significant (COP decreases by 0.48 for given range) compared to that of evaporator water inlet temperature (COP increases by 0.43 for given range). Comparisons of experimental values with simulated results show the maximum deviation of 5% for cooling capacity, 10% for heating capacity and 16% for system COP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Solar process heat in industrial systems – A global review
Farjana, S. H., Huda, N., Mahmud, M. A. P., & Saidur, R. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.065 · Cited by 269
Electrochemical Hydrogen Production: Sustainable Hydrogen Economy
Aslam, S., Rani, S., Lal, K., Fatima, M., Hardwick, T., Shirinfar, B., & Ahmed, N. (2023) · Green Chemistry · doi:10.1039/d3gc02849f · Cited by 263
Navigating challenges in large-scale renewable energy storage: Barriers, solutions, and innovations
Jafarizadeh, H., Yamini, E., Zolfaghari, S. M., Esmaeilion, F., Assad, M. E. H., & Soltani, M. (2024) · Energy Reports · doi:10.1016/j.egyr.2024.08.019 · Cited by 261
Metadata
- Authors
- Sarkar, J., & Bhattacharyya, S.
- Venue
- Archives of Thermodynamics
- Published
- 2011-11-01
- Volume
- 33
- Issue
- 4
- Pages
- 23-40
- ISSN
- 1231-0956 (ISSN-L)
- 2083-6023
- OpenAlex
- W2035290804
- Cited by
- 236
- References
- 0
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operating characteristics of transcritical CO2 heat pump for simultaneous water cooling and heating. https://app.cochat.ai/papers/10.2478/v10173-012-0026-8
- The paper
- Sarkar, J., & Bhattacharyya, S. (2011). Operating characteristics of transcritical CO2 heat pump for simultaneous water cooling and heating. Archives of Thermodynamics. https://doi.org/10.2478/v10173-012-0026-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.