Safety and efficacy of once-daily treatment with beclomethasone dipropionate nasal aerosol in subjects with perennial allergic rhinitis
The DOI matches its Crossref record.
Abstract
Intranasal corticosteroids are recommended as first-line therapy for the treatment of the symptoms of persistent allergic rhinitis (AR). Since the phase-out of chlorofluorocarbon nasal aerosols, intranasal corticosteroids have been available only as aqueous nasal sprays. This study was designed to assess the efficacy, safety, and quality-of-life benefits of beclomethasone dipropionate (BDP) hydrofluoroalkane nasal aerosol in subjects with perennial AR (PAR). After a 7- to 21-day placebo run-in period, eligible subjects aged ≥12 years with PAR were randomized to 6 weeks of once-daily treatment with BDP nasal aerosol at 320 μg or placebo. Reflective and instantaneous total nasal symptom scores (rTNSS and iTNSS, respectively), Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ) score, and physician-assessed total nasal symptom score were evaluated. The primary end point was change from baseline in average morning (A.M.) and evening (P.M.) subject-reported rTNSS over the 6-week treatment period. Safety and tolerability were also assessed. Treatment with BDP nasal aerosol showed significantly greater improvement in average A.M. and P.M. rTNSS compared with placebo (mean treatment difference, -0.84; 95% confidence interval, -1.2, -0.5; p < 0.001). Greater improvements in rTNSS were reported as early as day 1 and were maintained throughout the 6-week treatment period with the exception of day 2. Greater improvements were seen for all four individual nasal symptoms (nasal congestion, nasal itching, rhinorrhea, and sneezing) with BDP nasal aerosol compared with placebo. Similarly, significant improvements were seen in average A.M. and P.M. iTNSS (p < 0.001) and RQLQ score (p = 0.001) with BDP nasal aerosol compared with placebo. In addition, BDP nasal aerosol treatment was well tolerated, and its safety profile was comparable to that of placebo. This clinical study indicated that treatment with BDP nasal aerosol provides statistically significant and clinically meaningful nasal symptom relief accompanied by improved quality of life in subjects with PAR. Additionally, treatment with BDP nasal aerosol was well tolerated with a safety profile comparable to that of placebo. This study was part of the clinical trial NCT01134705 registered in www.ClinicalTrials.gov.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Practice Guideline: Allergic Rhinitis
Seidman, M. D., Gurgel, R. K., Lin, S. Y., Schwartz, S. R., Baroody, F. M., Bonner, J. R., Dawson, D. E., Dykewicz, M. S., Hackell, J. M., Han, J. K., et al. (2015) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599814561600 · Cited by 671
Nasal drug delivery devices: characteristics and performance in a clinical perspective—a review
Djupesland, P. G. (2013) · Drug Delivery and Translational Research · doi:10.1007/s13346-012-0108-9 · Cited by 563
International Consensus Statement on Allergy and Rhinology: Allergic Rhinitis
Wise, S. K., Lin, S. Y., Toskala, E., Orlandi, R. R., Akdis, C. A., Alt, J. A., Azar, A., Baroody, F. M., Bachert, C., Canonica, G. W., et al. (2018) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22073 · Cited by 557
International consensus statement on allergy and rhinology: Allergic rhinitis – 2023
Wise, S. K., Damask, C., Roland, L. T., Ebert, C., Levy, J. M., Lin, S., Luong, A., Rodriguez, K., Sedaghat, A. R., Toskala, E., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23090 · Cited by 507
Rhinitis 2020: A practice parameter update
Dykewicz, M. S., Wallace, D. V., Amrol, D. J., Baroody, F. M., Bernstein, J. A., Craig, T. J., Dinakar, C., Ellis, A. K., Finegold, I., Golden, D. B. K., et al. (2020) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2020.07.007 · Cited by 436
Self-citation
Metadata
- Authors
- Meltzer, E. O., Jacobs, R. L., LaForce, C. F., Kelley, C. L., Dunbar, S. A., & Tantry, S. K.
- Venue
- Allergy and Asthma Proceedings
- Publisher
- Oceanside Publications Inc.
- Published
- 2012-05-01
- Volume
- 33
- Issue
- 3
- Pages
- 249-257
- ISSN
- 1088-5412 (ISSN-L)
- OpenAlex
- W137185061
- Cited by
- 39
- References
- 0
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety and efficacy of once-daily treatment with beclomethasone dipropionate nasal aerosol in subjects with perennial allergic rhinitis. https://app.cochat.ai/papers/10.2500/aap.2012.33.3571
- The paper
- Meltzer, E. O., Jacobs, R. L., LaForce, C. F., Kelley, C. L., Dunbar, S. A., & Tantry, S. K. (2012). Safety and efficacy of once-daily treatment with beclomethasone dipropionate nasal aerosol in subjects with perennial allergic rhinitis. Allergy and Asthma Proceedings. https://doi.org/10.2500/aap.2012.33.3571
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.