Heat Transfer in High-Temperature Fibrous Insulation
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The combined radiation/conduction heat transfer in high-porosity, high-temperature fibrous insulations was investigated experimentally and numerically. The effective thermal conductivity of fibrous insulation samples was measured over the temperature range of 300-1300 K and environmental pressure range of 1.33 x 10(exp -5)-101.32 kPa. The fibrous insulation samples tested had nominal densities of 24, 48, and 72 kilograms per cubic meter and thicknesses of 13.3, 26.6 and 39.9 millimeters. Seven samples were tested such that the applied heat flux vector was aligned with local gravity vector to eliminate natural convection as a mode of heat transfer. Two samples were tested with reverse orientation to investigate natural convection effects. It was determined that for the fibrous insulation densities and thicknesses investigated no heat transfer takes place through natural convection. A finite volume numerical model was developed to solve the governing combined radiation and conduction heat transfer equations. Various methods of modeling the gas/solid conduction interaction in fibrous insulations were investigated. The radiation heat transfer was modeled using the modified two-flux approximation assuming anisotropic scattering and gray medium. A genetic-algorithm based parameter estimation technique was utilized with this model to determine the relevant radiative properties of the fibrous insulation over the temperature range of 300-1300 K. The parameter estimation was performed by least square minimization of the difference between measured and predicted values of effective thermal conductivity at a density of 24 kilograms per cubic meters and at nominal pressures of 1.33 x 10(exp -4) and 99.98 kPa. The numerical model was validated by comparison with steady-state effective thermal conductivity measurements at other densities and pressures. The numerical model was also validated by comparison with a transient thermal test simulating reentry aerodynamic heating conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heat transfer in fibrous materials
Bankvall, C. (1973) · Journal of Testing and Evaluation · doi:10.1520/jte10010j · Cited by 156 · cited 2×
“The radiant flux calculated from Eq. ( 5 ) was then used in Eq. (2) to obtain temperature distributions for the following time step.”
BackgroundMethodThermal Analysis and Design Optimization of Multilayer Insulation for Reentry Aerodynamic Heating
Daryabeigi, K. (2002) · Journal of Spacecraft and Rockets · doi:10.2514/2.3863 · Cited by 73
Self-citation
Cited by
Review of utilization of genetic algorithms in heat transfer problems
Gosselin, L., Tye-Gingras, M., & Mathieu-Potvin, F. (2009) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.11.015 · Cited by 410
Zhao, J.-J., Duan, Y.-Y., Wang, X.-D., & Wang, B.-X. (2012) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2012.02.037 · Cited by 81
Thermal Analysis and Design Optimization of Multilayer Insulation for Reentry Aerodynamic Heating
Daryabeigi, K. (2002) · Journal of Spacecraft and Rockets · doi:10.2514/2.3863 · Cited by 73
Self-citationLiu, Z., Li, Y., Xie, F., & Zhou, K. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.12.084 · Cited by 59
Metadata
- Authors
- Daryabeigi, K.
- Venue
- Journal of Thermophysics and Heat Transfer
- Published
- 2003-01
- Volume
- 17
- Issue
- 1
- Pages
- 10-20
- ISSN
- 0887-8722 (ISSN-L)
- 1533-6808
- OpenAlex
- W1985170137
- Cited by
- 140
- References
- 2
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.