The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Sensor placement for on-orbit modal identification and correlation of large space structures
Abstract
A method is presented for the selection of a set of sensor locations from a larger candidate set for the purpose of on-orbit identification and correlation of Large Space Structures. The method ranks the candidate sensor locations according to their contribution to the linear independence of the target modal partitions. In an iterative maner, the locations which do not contribute significantly are removed. The final sensor configuration tends to maximize determinant of the corresponding Fisher Information Matrix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
An Introduction to Statistical Communication Theory.
Bartlett, M. S., & Middleton, D. (1961) · Biometrika · doi:10.2307/2332785 · Cited by 466
A Methodology for Optimal Sensor Locations for Identification of Dynamic Systems
Shah, P. C., & Udwadia, F. E. (1978) · Journal of Applied Mechanics · doi:10.1115/1.3424225 · Cited by 138
Optimal sensor location for detecting changes in dynamical behavior
Basseville, M., Benveniste, A., Moustakides, G. V., et al. (1987) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1987.1104501 · Cited by 116
Detection and diagnosis of changes in the eigenstructure of nonstationary multivariable systems
Basseville, M., Albert Benveniste, A., Moustakides, G. V., & Rougée, A. (1987) · Automatica · doi:10.1016/0005-1098(87)90077-x · Cited by 95
Number and placement of control system components considering possible failures
Velde, W. E. V., & Carignan, C. R. (1984) · Journal of Guidance Control and Dynamics · doi:10.2514/3.19916 · Cited by 60
Cited by
Sensor Selection via Convex Optimization
Joshi, S., & Boyd, S. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2008.2007095 · Cited by 1,311
Optimal sensor placement methodology for parametric identification of structural systems
Papadimitriou, C. (2004) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2003.10.063 · Cited by 465
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
Digital twin, physics-based model, and machine learning applied to damage detection in structures
Ritto, T. G., & Rochinha, F. A. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.107614 · Cited by 367
Entropy-Based Optimal Sensor Location for Structural Model Updating
Papadimitriou, C., Beck, J. L., & Au, S.-K. (2000) · Journal of Vibration and Control · doi:10.1177/107754630000600508 · Cited by 337
Optimal sensor placement for fault detection
Worden, K., & Burrows, A. P. (2001) · Engineering Structures · doi:10.1016/s0141-0296(00)00118-8 · Cited by 331
Optimal sensor placement for structural health monitoring based on multiple optimization strategies
Yi, T., Li, H., & Gu, M. (2011) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.712 · Cited by 288
Computational methodologies for optimal sensor placement in structural health monitoring: A review
Tan, Y., & Zhang, L. (2020) · Structural Health Monitoring · doi:10.1177/1475921719877579 · Cited by 186
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23063293 · Cited by 146
Mustapha, S., Lu, Y., Ng, C.-T., & Malinowski, P. (2021) · Vibration · doi:10.3390/vibration4030033 · Cited by 84
Structural damage detection-oriented multi-type sensor placement with multi-objective optimization
Lin, J.-F., Xu, Y.-L., & Law, S.-S. (2018) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2018.01.047 · Cited by 83
Deep generative Bayesian optimization for sensor placement in structural health monitoring
Sajedi, S., & Liang, X. (2022) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12799 · Cited by 68
Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review
Sun, Z., Mahmoodian, M., Sidiq, A., Jayasinghe, S., Shahrivar, F., & Setunge, S. (2025) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan14020022 · Cited by 53
“However, this method has a primary drawback as it has been shown to be deficient in the presence of sensor noise and sensor failure, in situations of high modal density and in cases of model uncertainty [132].”
InfluentialLi, J., Hao, H., & Chen, Z. (2017) · Journal of Aerospace Engineering · doi:10.1061/(asce)as.1943-5525.0000550 · Cited by 44
Optimal sensor placement for damage detection of bridges subject to ship collision
Guo, Y. L., Ni, Y. Q., & Chen, S. K. (2017) · Structural Control and Health Monitoring · doi:10.1002/stc.1963 · Cited by 31
An Improved Genetic Algorithm for Optimal Sensor Placement in Space Structures Damage Detection
Beygzadeh, S., Salajegheh, E., Torkzadeh, P., Salajegheh, J., & Naseralavi, S. S. (2014) · International Journal of Space Structures · doi:10.1260/0266-3511.29.3.121 · Cited by 25
Data Compression for Multi-Parameter Estimation for Emitter Location
Chen, M., & Fowler, M. L. (2010) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2010.5417164 · Cited by 22
Sensor Placement for Structural Damage Detection considering Measurement Uncertainties
Zhou, X.-Q., Xia, Y., & Hao, H. (2013) · Advances in Structural Engineering · doi:10.1260/1369-4332.16.5.899 · Cited by 17
Ručevskis, S., Rogala, T., & Katunin, A. (2023) · Sensors · doi:10.3390/s23042290 · Cited by 5
Metadata
- Authors
- Kammer, D. C.
- Venue
- Journal of Guidance, Control, and Dynamics
- Published
- 1991-03
- Volume
- 14
- Issue
- 2
- Pages
- 251-259
- ISSN
- 0731-5090 (ISSN-L)
- 1533-3884
- OpenAlex
- W2065455374
- Cited by
- 935
- References
- 6
- FWCI
- 58.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.