The assessment of muscle strength is a task performed frequently by physical therapists. The purposes of this study were to determine whether intrasession test-retest reliability differs between make and break tests and strength tests that do not require an assessor (eg., isometric Kin-Com test) and hand-held dynamometer (HHD) assessments. The elbow flexor strength of 32 healthy, female volunteers was measured under four test conditions: Kin-Com make and break, and HHD make and break. Two measurements were performed for each test condition by the same rater. The results showed: 1) measurements obtained using the HHD deviated from a normal distribution, 2) comparable reliability coefficients for the make and break tests were obtained from the Kin-Com device, 3) there was a higher reliability coefficient for the make test compared with the break test for the HHD tests, and 4) the measured forces for the break tests were higher than the make tests. The results support the premise that hand-held dynamometry is a viable alternative to more costly modes of isometric strength measurements, provided the assessor's strength is greater than that of the specific muscle group being measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hand‐held Dynamometry Correlation With the Gold Standard Isokinetic Dynamometry: A Systematic Review
Stark, T., Walker, B., Phillips, J. K., Fejer, R., & Beck, R. (2011) · PM&R · doi:10.1016/j.pmrj.2010.10.025 · Cited by 816
Normative Values for Isometric Muscle Force Measurements Obtained With Hand-held Dynamometers
Andrews, A. W., Thomas, M. W., & Bohannon, R. W. (1996) · Physical Therapy · doi:10.1093/ptj/76.3.248 · Cited by 705
Test-retest strength reliability: Hand-held dynamometry in community-dwelling elderly fallers
Wang, C.-Y., Olson, S. L., & Protas, E. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32743 · Cited by 314
Byram, I. R., Bushnell, B. D., Dugger, K., Charron, K., Harrell, F. E., & Noonan, T. J. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546509360404 · Cited by 307
Kelln, B. M., McKeon, P. O., Gontkof, L. M., & Hertel, J. (2008) · Journal of Sport Rehabilitation · doi:10.1123/jsr.17.2.160 · Cited by 267
Metadata
- Authors
- Stratford, P. W., & Balsor, B. E.
- Venue
- Journal of Orthopaedic & Sports Physical Therapy
- Published
- 1994-01
- Volume
- 19
- Issue
- 1
- Pages
- 28-32
- ISSN
- 0190-6011 (ISSN-L)
- 1938-1344
- OpenAlex
- W1987494262
- Cited by
- 251
- References
- 0
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comparison of Make and Break Tests Using a Hand-Held Dynamometer and the Kin-Com. https://app.cochat.ai/papers/10.2519/jospt.1994.19.1.28
- The paper
- Stratford, P. W., & Balsor, B. E. (1994). A Comparison of Make and Break Tests Using a Hand-Held Dynamometer and the Kin-Com. Journal of Orthopaedic & Sports Physical Therapy. https://doi.org/10.2519/jospt.1994.19.1.28
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.