The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
ANALYSIS OF VITAL SIGNS MONITORING USING AN IR-UWB RADAR
Open accessAbstract
Ultra-wide Band (UWB) technology is a new, useful and safe technology in the field of wireless body networks.This paper focuses on the feasibility of estimating vital signs -specifically breathing rate and heartbeat frequency -from the spectrum of recorded waveforms, using an impulse-radio (IR) UWB radar.To this end, an analytical model is developed to perform and interpret the spectral analysis.Both the harmonics and the intermodulation between respiration and heart signals are addressed.Simulations have been performed to demonstrate how they affect the detection of vital signs and also to analyze the influence of the pulse waveform.A filter to cancel out breathing harmonics is also proposed to improve heart rate detection.The results of the experiments are presented under different scenarios which demonstrate the accuracy of the proposed technique for determining respiration and heartbeat rates.It has been shown that an IR-UWB radar can meet the requirements of typical biomedical applications such as non-invasive heart and respiration rate monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staderini, E. M. (2002) · IEEE Aerospace and Electronic Systems Magazine · doi:10.1109/62.978359 · Cited by 496
The Chirp z-Transform Algorithm and Its Application
Rabiner, L. R., Schafer, R. W., & Rader, C. M. (1969) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1969.tb04268.x · Cited by 344
Implementation and analysis of respiration-rate estimation using impulse-based UWB
Venkatesh, S., Anderson, C. R., Rivera, N. V., & Buehrer, R. M. (2005) · MILCOM 2005 - 2005 IEEE Military Communications Conference · doi:10.1109/milcom.2005.1606167 · Cited by 179
UWB radar for patient monitoring
Immoreev, I. Y., & Tao, T.-H. (2008) · IEEE Aerospace and Electronic Systems Magazine · doi:10.1109/maes.2008.4693985 · Cited by 119
Bio-Medical Sensing using Ultra Wideband Communications and Radar Technology: A Feasibility Study
Bilich, C. G. (2006) · doi:10.1109/pcthealth.2006.361671 · Cited by 86
Singh, M. C., & Ramachandran, G. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.81568 · Cited by 67
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
FarSense: Pushing the Range Limit of WiFi-based Respiration Sensing with CSI Ratio of Two Antennas
Zeng, Y., Wu, D., Xiong, J., Yi, E., Gao, R., & Zhang, D. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3351279 · Cited by 469
Bi-directional passing people counting system based on IR-UWB radar sensors
Choi, J. W., Quan, X., & Cho, S. H. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2714181 · Cited by 102
Non-Contact Vital Signs Monitoring of Dog and Cat Using a UWB Radar
Wang, P., Ma, Y., Liang, F., Zhang, Y., Yu, X., Li, Z., An, Q., Lv, H., & Wang, J. (2020) · Animals · doi:10.3390/ani10020205 · Cited by 45
Metadata
- Authors
- Lazaro, A., Girbau, D., & Villarino, R.
- Venue
- Progress In Electromagnetics Research
- Publisher
- The Electromagnetics Academy
- Published
- 2010
- Volume
- 100
- Pages
- 265-284
- ISSN
- 1070-4698 (ISSN-L)
- 1559-8985
- OpenAlex
- W2134639649
- Cited by
- 401
- References
- 6
- FWCI
- 10.92
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ANALYSIS OF VITAL SIGNS MONITORING USING AN IR-UWB RADAR. https://app.cochat.ai/papers/10.2528/pier09120302
- The paper
- Lazaro, A., Girbau, D., & Villarino, R. (2010). ANALYSIS OF VITAL SIGNS MONITORING USING AN IR-UWB RADAR. Progress In Electromagnetics Research. https://doi.org/10.2528/pier09120302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.