18F-Dihydroxyphenylalanine PET in Patients with Biochemical Evidence of Medullary Thyroid Cancer: Relation to Tumor Differentiation
Open accessThe DOI matches its Crossref record.
Abstract
UNLABELLED: Curative treatment for recurrent medullary thyroid cancer (MTC), diagnosed by rising serum calcitonin, is surgery, but tumor localization is difficult. Therefore, the value of 18F-dihydroxyphenylalanine PET (18F-DOPA PET), 18F-FDG PET, (99m)Tc-V-di-mercaptosulfuricacid (DMSA-V) scintigraphy, and MRI or CT was studied. METHODS: Twenty-one patients with biochemical recurrent or residual MTC underwent 18F-DOPA PET, 18F-FDG PET, DMSA-V scintigraphy, and MRI or CT. Patient- and lesion-based sensitivities were calculated using a composite reference consisting of all imaging modalities. RESULTS: In 76% of all patients with MTC, one or more imaging modalities was positive for MTC lesions. In 6 of 8 patients with a calcitonin level of <500 ng/L, imaging results were negative. In 15 patients with positive imaging results, 18F-DOPA PET detected 13 (sensitivity, 62%; with 4.6 lesions per patient [lpp]). Morphologic imaging (n = 19) was positive in 7 (sensitivity, 37%; 4.7 lpp), DMSA-V (n = 18) in 5 (sensitivity, 28%; 1.1 lpp), and 18F-FDG PET (n = 17) in 4 (sensitivity, 24%; 1.6 lpp). In a lesion-based analysis, 18F-DOPA PET detected 95 of 134 lesions (sensitivity, 71%), morphologic imaging detected 80 of 126 (sensitivity, 64%), DMSA-V detected 20 of 108 (sensitivity, 19%), and 18F-FDG PET detected 48 of 102 (sensitivity, 30%). In 2 of 3 patients with a calcitonin/carcinoembryonic antigen (CEA) doubling time of < or =12 mo, 18F-FDG PET performed better than 18FDOPA PET; in the third patient, 18F-FDG PET was not performed. CONCLUSION: MTC lesions are best detectable when serum calcitonin was >500 ng/L. 18F-DOPA PET is superior to 18F-FDG PET, DMSA-V, and morphologic imaging. With short calcitonin doubling times (< or =12 mo), 18F-FDG PET may be superior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wells, S. A., Asa, S. L., Dralle, H., Elisei, R., Evans, D. B., Gagel, R. F., Lee, N., Machens, A., Moley, J. F., Pacini, F., et al. (2015) · Thyroid · doi:10.1089/thy.2014.0335 · Cited by 2,444
Medullary Thyroid Cancer: Management Guidelines of the American Thyroid Association
Kloos (Chair), R. T., Eng, C., Evans, D. B., Francis, G. L., Gagel, R. F., Gharib, H., Moley, J. F., Pacini, F., Ringel, M. D., Schlumberger, M., et al. (2009) · Thyroid · doi:10.1089/thy.2008.0403 · Cited by 1,357
Innovative imaging of insulinoma: the end of sampling? A review
Christ, E., Antwi, K., Fani, M., & Wild, D. (2020) · Endocrine-Related Cancer · doi:10.1530/erc-19-0476 · Cited by 78
Contemporary nuclear medicine imaging of neuroendocrine tumours
Wong, K. K., Waterfield, R. T., Marzola, M. C., Scarsbrook, A. F., Chowdhury, F. U., Gross, M. D., & Rubello, D. (2012) · Clinical Radiology · doi:10.1016/j.crad.2012.03.019 · Cited by 45
Metadata
- Authors
- Koopmans, K. P., de Groot, J. W. B., Plukker, J. T. M., de Vries, E. G. E., Kema, I. P., Sluiter, W. J., Jager, P. L., & Links, T. P.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-03-28
- Volume
- 49
- Issue
- 4
- Pages
- 524-531
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2125379832
- Cited by
- 121
- References
- 0
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.