Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 199

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison Between the Prognostic Value of Left Ventricular Function and Myocardial Perfusion Reserve in Patients with Ischemic Heart Disease

Open access
Tio, René A., Dabeshlim, Ali, Siebelink, Hans-Marc J., de Sutter, Johan, Hillege, Hans L., Zeebregts, Clark J., Dierckx, Rudi A.J.O., van Veldhuisen, Dirk J., Zijlstra, Felix, Slart, Riemer H.J.A. · 2009 · Journal of Nuclear Medicine

Abstract

UNLABELLED: The purpose of this study was to compare the prognostic value of left ventricular ejection fraction (LVEF) and myocardial perfusion reserve (MPR) assessed with PET in patients with ischemic heart disease (IHD). Myocardial perfusion is the main determinant of left ventricular function in patients with IHD. The prognostic value of LVEF has been widely established. In addition, MPR determines survival in patients with hypertrophic and dilated cardiomyopathies. In the present study, we evaluated whether MPR also determines survival in patients with IHD. METHODS: Between 1995 and 2003, 480 consecutive patients with chronic IHD underwent dipyridamole stress and rest 13N-ammonia PET to determine MPR. Additionally, 18F-FDG PET was performed for viability (mismatching defects), infarction (matching defects), and left ventricular function assessment. Patients were followed for all causes of mortality and major cardiovascular events. RESULTS: In 463 of the 480 patients, valid MPR could be measured (368 men; mean age, 66+/-11 y; LVEF, 35%+/-15%). One hundred nineteen patients underwent a PET-driven revascularization (67 through percutaneous coronary intervention and 52 through coronary artery bypass grafting). The remaining 344 patients were the subject of this study. The overall MPR was 1.71+/-0.50 (intertertile boundaries, 1.49 and 1.84). After adjustment for age and sex, MPR was associated with a hazard ratio for cardiac death of 4.11 (95% confidence interval, 2.98-5.67) per SD decrease, whereas the risk for LVEF was 2.76 (2.00-3.82) per SD decrease. CONCLUSION: Patients with IHD with a low MPR are at high risk of cardiac death. MPR is a more sensitive predictor for cardiac death than is LVEF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.108.054395

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 199

Metadata

Authors
Tio, R. A., Dabeshlim, A., Siebelink, H.-M. J., de Sutter, J., Hillege, H. L., Zeebregts, C. J., Dierckx, R. A. J. O., van Veldhuisen, D. J., Zijlstra, F., & Slart, R. H. J. A.
Venue
Journal of Nuclear Medicine
Published
2009-01-21
Volume
50
Issue
2
Pages
214-219
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2102612506
Cited by
199
References
1
FWCI
14.56
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison Between the Prognostic Value of Left Ventricular Function and Myocardial Perfusion Reserve in Patients with Ischemic Heart Disease. https://app.cochat.ai/papers/10.2967/jnumed.108.054395
The paper
Tio, R. A., Dabeshlim, A., Siebelink, H.-M. J., de Sutter, J., Hillege, H. L., Zeebregts, C. J., Dierckx, R. A. J. O., van Veldhuisen, D. J., Zijlstra, F., & Slart, R. H. J. A. (2009). Comparison Between the Prognostic Value of Left Ventricular Function and Myocardial Perfusion Reserve in Patients with Ischemic Heart Disease. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.108.054395

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.